Blizzard VFT NU-99729VFT -86°C Ultralow Freezer

The Blizzard VFT NU-99729VFT delivers ENERGY STAR-certified -86°C ultralow temperature storage in a nominal 729-liter (25.7 cu. ft.) footprint, balancing substantial sample capacity with energy efficiency engineered for long-term, around-the-clock laboratory operation.
The Blizzard VFT NU-99729VFT delivers ENERGY STAR-certified -86°C ultralow temperature storage in a nominal 729-liter (25.7 cu. ft.) footprint, balancing substantial sample capacity with energy efficiency engineered for long-term, around-the-clock laboratory operation.

Overview

For laboratories managing growing sample collections, the Blizzard VFT NU-99729VFT -86°C Ultralow Temperature Freezer provides a nominal 729-liter (25.7 cu. ft.) internal volume of ultralow temperature storage — accommodating up to 50,000 two-milliliter vials across 20 racks. It is the most widely specified model in the Blizzard VFT Series, combining meaningful capacity with ENERGY STAR-certified efficiency.

Variable Frequency Technology (VFT) continuously modulates compressor speed to match real-time thermal demand, achieving ENERGY STAR-certified performance at 8.1 kWh per day. Two selectable operating modes allow your team to adapt to the moment: High Performance mode for tightest temperature uniformity, or Energy Saving mode for reduced power consumption during stable, long-term archiving.

Four independent inner door sections minimize thermal disturbance during sample access, isolating each retrieval event to a single compartment while the remaining three maintain stable conditions. A 22-hour battery backup system sustains alarm coverage — monitoring temperature, power status, door position, probe integrity, condenser condition, and battery state — throughout power disruptions.

Performance data is available via touchscreen LCD display, USB data export, or RS-485 transmission to external monitoring systems. R290/R170 hydrocarbon refrigerant provides near-zero global warming potential, supporting current environmental compliance requirements and responsible laboratory practice. The NU-99729VFT accepts 100–230V / 50–60Hz electrical input. To request a quote or discuss your application, contact NuAire.

Frequently Asked Questions

What temperature does the Blizzard VFT NU-99729VFT reach?

The NU-99729VFT maintains temperatures from -40°C to -86°C with ±3°C temperature uniformity throughout the interior. Variable Frequency Technology continuously adjusts compressor output to sustain stable ultralow temperature storage.

What is the nominal capacity of the NU-99729VFT?

The NU-99729VFT has a nominal internal volume of 729 liters (25.7 cu. ft. nominal), storing up to 500 two-inch (5 cm) boxes across 20 racks, or approximately 50,000 two-milliliter vials.

Is the Blizzard VFT NU-99729VFT ENERGY STAR certified?

Yes. The NU-99729VFT is ENERGY STAR certified with measured energy consumption of 8.1 kWh per day. Two operating modes — High Performance and Energy Saving — allow labs to optimize for temperature control or energy efficiency.

How long does battery backup last on the NU-99729VFT?

The NU-99729VFT provides 22 hours of battery-backed alarm monitoring — covering temperature, power failure, door-ajar status, probe failure, condenser condition, and battery state throughout power interruptions.

What refrigerant does the NU-99729VFT use?

The NU-99729VFT uses R290 and R170 hydrocarbon refrigerants, both carrying near-zero global warming potential — supporting compliance with current and anticipated environmental refrigerant regulations.

ENERGY STAR Certified: 8.1 kWh/day

Variable Frequency Technology adapts compressor output in real time, achieving ENERGY STAR-certified energy consumption of 8.1 kWh per day. High Performance and Energy Saving modes allow your team to optimize for temperature control or energy economy.

Four Independent Inner Doors

Four thermally isolated inner door compartments concentrate thermal disturbance on the zone being accessed, keeping the remaining sample inventory undisturbed, essential in laboratories with frequent retrieval activity.

22-Hour Battery Backup

22-hour battery-backed alarm coverage maintains monitoring of temperature, power status, door position, probe integrity, condenser condition, and battery state during power events — protecting the samples your research depends on.

Hydrocarbon Refrigerant: Near-Zero GWP

R290/R170 hydrocarbon refrigerant combines effective thermodynamic performance with near-zero global warming potential — supporting current environmental compliance requirements and positioning labs for anticipated future refrigerant standards.

Data Export and Remote Monitoring Ready

Monitor freezer performance on the touchscreen LCD display, download logged data directly via USB, or transmit via RS-485 to laboratory data management and remote monitoring systems.

Specifications

Blizzard VFT NU-99729VFT -86°C Ultralow Freezer
2-inch Box Capacity 500
Rack Capacity 20
2 mL Vial Capacity 50,000
Access Port Location Back Wall
Back Up Battery for Alarm Functions High/low temperature, power failure, door open, sensor failure, high ambient temperature, hot condenser and low battery alarms
Cabinet Thickness Inches (mm) 3.5 (90)
Casters All-direction caster with fixing stand
Door Thickness Inches (mm) 3.5 (90)
Exterior Door Single Door
Exterior Door Seal Quadruple Seal on the Outside Door
Exterior Material Color Coating Cold Plate Steel
Fan Brand EBM
Inner Doors 4
Insulation VIP+CFC Free Foaming Agent
Interior Door Seal Single Seal on all Interior Doors
Interior Material Color Coating Electric Zinc Steel Plate
Leg Levelers 2
Locking Mechanism Key
Shelf Capacity lbs (kg) 199 (90)
Shelf Material Stainless Steel
Shelves 3 Shelves, 4 Locations
Style Upright
Adjustable High/Low Temperature Alarms True
Alarms Temperature, Power Failure, Probe Failure, Condenser, Ambient Temperature, Door Ajar, Low Battery, etc.
Auto Voltage Safeguard Included
Data Output Features USB, RS-485
Power Switch On-Off with Circuit Breaker
Remote Alarm Terminals Remote Alarm Port, RS232 / RS485 (Optional)
Setpoint Security Yes
Est. Shipping Depth Inches (mm) 42 (1067)
Est. Shipping Height Inches (mm) 84 (2137)
Est. Shipping Width Inches (mm) 44 (1118)
Exterior Depth Inches (mm) 38.6 (980)
Exterior Depth with Door Open Inches (mm) 74.80 (1900)
Exterior Height Inches (mm) 78 (1980)
Exterior Width Inches (mm) 41.2 (1046)
Footprint Depth inches (mm) 38.6 (980)
Footprint Width inches (mm) 41.2 (1046)
Interior Depth Inches (mm) 28.2 (716)
Interior Height Inches (mm) 51.6 (1310)
Interior Volume Cubic Feet (Liters) 25.7 (729)
Interior Width Inches (mm) 30.2 (766)
Shelf Depth Inches (mm) 26.6 (677)
Shelf Width Inches (mm) 29.5 (750)
Electric Protection Type Class I
Electrical Configuration 100-230V, Variable Frequency
Input Power (W) 1650
Power Consumption KWh/day 8.1
Power Cord Grounded Three Prong Power Plug, Rated 16A
Power Cord Length Foot (Meter) 8.2 ft (2.5m)
Rated Voltage (V) 100-230
Sound Level 43.5 dB(A)
1 Minutes Door Open Recovery Time (25°C ambient running temp -75°C) in Minutes 45
Cool Down Time (25°C ambient to -80°C) in Minutes 310
Heat Rejected (BTU/Hour) 1404
Warm-Up Time (25°C ambient -80°C to -50°C) in Minutes 270
Safety Certification Energy Star, UL, CE, UKCA
Compressor Capacity Watt 950
Compressor Type/Brand/Number Hermetic Reciprocating Type / SECOP / 2
Condenser Type Enhanced Micro-Channel & Forced-Air Cooled
Defrost Method Manual
Evaporator Type Cold Wall With Enhanced Heat Transfer Treatment
Refrigeration System Type Direct cooling
Ambient Temperature (°C) 10 to 32
Temperature Accuracy °C ±1
Temperature Control Microprocessor Controller with Touchscreen
Temperature Range °C -40 to -86
Temperature Sensor Type RTD (Pt100)
Temperature Uniformity °C ±3
Est. Shipping Weight lbs (kg) Estimated 849 lbs (385 kgs)
Net Weight lbs (kg) 761 lbs (345 kg)

Request Your Quote for a NU-99729VFT