PharmaGard ES NU-NTE800 Total Exhaust Compounding Aseptic Containment Isolator

The PharmaGard ES NTE800 Total Exhaust Compounding Containment Pharmacy Isolator creates negative pressure ISO Class 5 clean air environment for aseptic compounding of hazardous drugs and chemotherapy drugs to meet USP 797 and 800 requirements.

Part #: NU-NTE800

Features

Meet USP 797 and USP 800 requirements when compounding hazardous drugs with this PharmaGard total exhaust compounding aseptic containment isolator. It creates a negative-pressure ISO Class 5 clean-air environment to prevent contamination and protect personnel when compounding hazardous sterile preparations.


Ergonomics

Expanded Work Zone Supports Flexible Workflow

The large work zone lets workers place the interchange on the left or right sides of the 4-foot units, or on the left, right, or both sides at once of the 6-foot units. This provides each worker with a customized work space for increased comfort and reduced arm, neck and shoulder strain.


Easy Access

The oval slanted glove ports and the six-hook, three-position IV bar improve your reach while ensuring proper compounding distance and height.


Optional Adjustable Base Encourages Comfortable Work Posture

Provide maximum knee and thigh clearance and proper height for optimal leg and upper-body support with the adjustable base.


Improved Viewing

The cool white lighting and open sight lines help workers see the work area more clearly.


Safety

Meets USP 797 Standards

Provide a certified ISO Class 5 sterile environment with this compounding aseptic containment isolator (CACI), which meets or exceeds the requirements of USP 797 for moving product in and out and for containing particulates and volatile gases. The HEPA-filtered interchange compartment maintains a negative pressure relative to the work area, which operates at a negative air pressure relative to the surrounding room. This minimizes the possibility of hazardous materials migrating from the workspace into the surrounding room, and of contamination migrating into the work zone.


Meets USP 800 Standards

Use this CACI, which meets USP 800 standards, to adequately protect personnel and the environment outside the pharmacy when handling hazardous drugs.


Remove Sharps and Waste Quickly

Protect workers from sharps and waste, which are disposed of through covered negative-pressure drop tubes. This waste system maintains sterility and increases workspace. A locking mechanism with an airtight seal holds the waste containers in place under the work surface, and the containers can be quickly released, removed and replaced.


Inner Transfer Window Isolates Sterile Product

The counterbalanced transfer window separates the inter-chamber from the sterile work zone. A security lock ensures the inner transfer door remains locked if the outer door is open. Workers can quickly move the transfer window up or down with one finger.


Seamlessly Transfer Compounding Material

A removable stainless steel tray located in the transfer compartment is mounted on ball-bearing brackets to let workers smoothly move compounding materials into and out of the work area. The tray has coved corners to make it easier to keep clean and sterile.


Performance

Ultrahigh-Efficiency Motor

Reduce energy costs and increase filter life with the ultrahigh-efficiency motor.


Specs


Catalog Number

Catalog Number

NU-NTE800-400

Nominal 4 foot (1.2m)

NU-NTE800-600

Nominal 6 foot (1.8m)

Performance Specifications

1. Product Protection

CETA CAG-002-2006

ISO Class 5 (Laminar Flow)

CETA CAG-002-2006

ISO Class 5 (Laminar Flow)

Style of Isolator

Bench top/console Isolator

Bench top/console Isolator

Isolator Construction

Welded stainless steel 16GA, Type 304 pressure tight design

Welded stainless steel 16GA, Type 304 pressure tight

design

Interchange Chamber

ISO Class 5 With Internal/External Sealed Doors

ISO Class 5 With

Internal/External Sealed Doors

Diffuser for Air Supply (Metal)

Non-flammable

Non-flammable

HEPA Filter Seal Type:

Supply Filter-99.99% Eff. on 0.3 microns

Exhaust Filter-99.99% Eff. on 0.3 microns


Neoprene, Spring loaded Under Negative Pressure


Neoprene, Spring loaded Under Negative Pressure

Standard Services:

Hospital Grade Duplex Outlet


One, Backwall


One, Backwall

Optional Services:

Service Valves 3/8" NPT


Up to 3


Up to 3

Isolator Size Inches (mm): Height

Height (Center of Glove Port at 46-1/8) Width

Depth (with Control Center)


61 (1550)

92 1/2 (2350)

50 (1270)

32 1/2 (826)


61 (1550)

92 1/2 (2350)

74 (1880)

32 1/2 (826)

Work Zone Inches (mm): Width

Height

Depth (Center of Glove Port)


35 1/4 (895)

27 3/8 (695)

23 1/4 (591)


59 1/4 (1505)

27 3/8 (695)

23 1/4 (591)

Interchange Inches (mm) Width

Depth (at Work Surface) Height


14 1/8 (359)

24 (610)

27 3/8 (695)


14 1/8 (359)

24 (610)

27 3/8 (695)

Hinged Lockable Viewing Window (Polycarbonate)

Fully closed to fully open

Fully closed to fully open

Exhaust CFM/CMH Standard:

Plan Duct Static Pressure Eng/Metric: (water gauge)

550/934

2.0”w.g./50.8 mm w.g.

725/1232

2.0”w.g./50.8 mm w.g.

Heat Rejected, BTU, Per Hour

539

880

Electrical: Volts, AC 60 Hz

Amps: Blower/Lights

Amps: Hospital Grade Duplex Amps: Total

12 ft. Hospital Grade Power Cord (one)

UL/UL-C Listed 115

3

3

6

14 GA - 3 Wire, 15A

UL/UL-C Listed 115

5

3

8

14 GA - 3 Wire, 15A

*Crated Shipping Weight:

*Net Weight:

Net Optional Adjustable Automatic Base Stand Wt: Net Optional Telescoping Base Stand Wt:

Net Optional Bench Mount Wt:

515 lbs./234 kg.

465 lbs./211 kg.

150 lbs./68 kg.

60 lbs./27 kg.

20 lbs./19 kg.

665 lbs./302 kg.

615 lbs./279 kg.

160 lbs./73 kg.

70 lbs./32 kg.

20 lbs./19 kg.


* For total weight, must select and add (1) of (3) base options.