Discovery the proper accessories needed when exhausting NuAire airflow products.
The Alnor® AirGard® airflow monitor model NU-AIN-315BSC monitors the biological safety cabinet exhaust airflow performance providing a visual and audible alarm in case of loss of airflow.
The Alnor® AirGard® airflow monitor model NU-AIN-350CEM monitors the biological safety cabinet exhaust airflow performance providing a visual and audible alarm in the event the cabinet increase or decreases airflow.
The Alnor® AirGard® airflow monitor model NU-AIN-I315BSC monitors the biological safety cabinet exhaust airflow performance providing a visual and audible alarm in case of loss of airflow.
The Digital Manometer Monitor uses an integrated digital pressure transducer to monitor exhaust system negative pressure. The monitor indicates through both a segment display and LED's. The segment display is green and operates to + 0.01" w.g. sensitivity. The LED's indicate acceptable pressure (green), caution or near alarm points to within 0.005" w.g. (yellow) or alarm condition (red).
IT IS RECOMMENDED THAT THE MONITOR BE CALIBRATED ANNUALLY.
The Digital Manometer Monitor uses an integrated digital pressure transducer to monitor exhaust system negative pressure. The monitor indicates through both a segment display and LED's. The segment display is green and operates to + 0.01" w.g. sensitivity. The LED's indicate acceptable pressure (green), caution or near alarm points to within 0.005" w.g. (yellow) or alarm condition (red).
IT IS RECOMMENDED THAT THE MONITOR BE CALIBRATED ANNUALLY.
The NU-907 Fixed Range Exhaust Transition provides an air gap between the exhaust efflux of the BSC and the transition. The air gap essentially insulates the BSC from potential variations of airflow in the plant exhaust system, particularly if multiple BSC's are connected to the same exhaust blower system. NuAire's canopy employs a one-inch air-gap with a recommended minimum airflow through the gap of 175 LFPM (.89 m/s) nominally 200 LFPM (1.016 m/s). The characteristics of Canopy Transitions are as follows:
Compatible Models: NU-475 / 477 / 480 / 481
Combine with NU-AIN-315BSC low flow exhaust monitor to comply with Standard NSF/ANSI 49.
The NU-926/916 Fixed Range Exhaust Transition provides an air gap between the exhaust efflux of the BSC and the transition. The air gap essentially insulates the BSC from potential variations of airflow in the plant exhaust system, particularly if multiple BSC's are connected to the same exhaust blower system. NuAire's canopy employs a one-inch air-gap with a recommended minimum airflow through the gap of 175 LFPM (.89 m/s) nominally 200 LFPM (1.016 m/s). The characteristics of Canopy Transitions are as follows:
Compatible Models: NU-407 425 / 437 / 440 / 602 / 629
Combine with NU-AIN-315BSC low flow exhaust monitor to comply with Standard NSF/ANSI 49.
Flex duct to connect exhaust systems to NuAire Airflow Products providing flexibility when used with adjustable base stands.
- 8 ft. (2.5 m) of Flex Duct
- Two (2) Stainless Steel Band Clamps
Flex duct to connect exhaust systems to NuAire Airflow Products providing flexibility when used with adjustable base stands.
- 8 ft. (2.5 m) of Flex Duct
- Two (2) Stainless Steel Band Clamps
Flex duct to connect exhaust systems to NuAire Airflow Products providing flexibility when used with adjustable base stands.
- 8 ft. (2.5 m) of Flex Duct
- Two (2) Stainless Steel Band Clamps
Flex duct to connect exhaust systems to NuAire Airflow Products providing flexibility when used with adjustable base stands.
- 8 ft. (2.5 m) of Flex Duct
- Two (2) Stainless Steel Band Clamps
The FlowGard monitor connects to the positive pressure port on NuAire airflow products to monitor and alarm for high and low airflow.
The FlowGard monitor uses a digital pressure transducer to monitor positive or negative pressure. The FlowGard monitor indicates through LED's normal operation (green), as well as high alarm status (red) and low alarm status (red).
Compatible Models: NU-425 / 437 / 475 / 477 / 602 / 629 / 806 / 813 / 819 / 126
Note: Cabinet or duct system must be new or have been decontaminated before installing the NU-956.
The FlowGard monitor connects to the positive pressure port on NuAire airflow products to monitor and alarm for high and low airflow.
The FlowGard monitor uses a digital pressure transducer to monitor positive or negative pressure. The FlowGard monitor indicates through LED's normal operation (green), as well as high alarm status (red) and low alarm status (red).
Compatible Models: NU-425 / 437 / 475 / 477 / 602 / 629 / 806 / 813 / 819 / 126
Note: Cabinet or duct system must be new or have been decontaminated before installing the NU-956.