Pharmacy
Learn more about NuAire pharmacy products and best practices.
-
[Brochure] LabGard AIR NU-543 Class II, Type A2 Biosafety Cabinet
LabGard AIR Model NU-543 Class II, Type A2 Biosafety Cabinet provides long lasting personnel, product, and environmental protection through advanced construction techniques and electronic controls.
-
[Bulletin] Clarifying the Class II, Type C1 Biosafety Cabinet
The Class II, Type C1 Biosafety Cabinet (BSC) is similar to a Type B1 regarding airflow pattern. The Type C1 has a portion of the work surface to exhaust air.
-
[Infographic] Biosafety Cabinet Operating Label
Learn the proper use procedures from start up to shut down when using your Biosafety Cabinet.
-
[Infographic] 5 Biosafety Cabinet Reminders
We asked NIH National Biosafety and Biocontainment Fellows what some of the most common mistakes made when working with a Biosafety Cabinet.
-
[Infographic] Hazardous Drug Biosafety Cabinet Operating Procedure
When working in your biosafety cabinet with hazardous drugs it is important to learn the proper procedure from beginning to end.
-
[Infographic] 10 Tips for Working Safely in the laboratory with Your Biosafety Cabinet
Good technique when working within a Class II Biosafety Cabinet will minimize air turbulence and prevent splatter or unwanted spread of aerosols.
-
Shop Pharmacy Equipment
Click Here -
[ebook] 10 Steps to Cleaning a Spill in a Biosafety Cabinet
It happens at some point to even the most seasoned laboratory technician that a spill occurs within the Biosafety Cabinet (BSC). Here are a few steps to cleaning a spill in a BSC.
-
[White Paper] Part 1: Facility and Engineering Control Design Under USP <800>
The focus of this article is to discuss the details for consideration of a good working design of a USP 800 compliant compounding lab.
-
[Bulletin] Camera Usage in a Biosafety Cabinet and Pharmacy Isolator
NuAire offers general guidance to aid in the selection of camera systems that can be mounted on or near your primary engineering controls.
-
[Bulletin] Impact of Class II Biosafety Cabinet Downflow Velocity on Cross Contamination
The result of lower Biosafety Cabinet downflow velocities result in a higher level of sample cross-contamination using traditional work practice guidelines.
-
[Bulletin] Movement and Re-Certification of a Biosafety Cabinet
-
NU-NTE800 Performance Evaluation Compliance to USP 797 / USP 800
-
[Bulletin] Use of Anesthetic Gas Isoflurane within a Biosafety Cabinet
Surgical procedures using Anesthetic Gas in the vivarium that require a sterile or contained environment should be performed in a biosafety cabinet (BSC).
-
NU-NR800 Performance Evaluation Compliance to USP 797 / USP 800
-
[Bulletin] When to Replace My Biosafety Cabinet
Biosafety Cabinets have a 15 year useable life. Read this bulletin to answer the question when to replace your biosafety cabinet.
-
NU-PR797 Performance Evaluation Compliance to USP 797
-
[Bulletin] Chemo Pad Containment Capability of a Biosafety Cabinet
Performance capabilities of a NuAire biosafety cabinet (BSC) using a chemotherapy pad on the worksurface.
-
[Bulletin] Natural Gas use in a Biosafety Cabinet
Bunsen burners and natural gas use within biosafety cabinet present inherent problems and are not needed or recommended unless deemed absolutely necessary.
-
[White Paper] Industry Standards Your Biosafety Cabinet Should Meet
By purchasing BSC's that adhere to Biosafety Cabinet Industry Standards, customers can be confident that they are working with BSC's that meet industry guidelines.
-
[White Paper] Purchasing a Biosafety Cabinet, Who to Involve
As a Principal Investigator learn who you should invovle when purchasing a biosafety cabinet (BSC).
-