LabGard ES AIR NU-543 Class II Type A2 Biosafety Cabinet

The NU-543 is configurable for a broad range of applications and geographies with a choice of NSF listed access openings, an optional smooth interior, EN 12469 listed configurations, and a global supply chain.

Overview

The NU-543 carries the LabGard® value proposition across the boundaries of geography and scientific applications by offering the broadest choice of configurations. This model features a dual thermistor airflow sensor and alphanumeric display for laboratories requiring a clear measurement of their cabinet’s performance and a choice of three NSF listed work access openings for procedures needing ergonomic access to the work zone. The cabinet can optionally be made with a smooth interior for procedures such as pharmacy compounding and always includes a prop up work tray to ease regular cleaning under the work surface. Double exhaust filters can be fitted to meet the requirements of an application or national guidelines. A truly global product, models are available that meet NSF/ANSI 49 and EN 12469, feature multilingual displays, and can ship from multiple locations around the world. * *Some options and configurations are only available from North America. Consult NuAire for details.

FlowGard Control System

The FlowGard control system calculates inflow velocity based on the data received from the exhaust airflow sensor and displays it on the front screen. Alphanumeric readouts, nearby membrane buttons, and a choice of 6 world languages all make navigating this system's user and service menus easy.

FlowGard Electronic Controls System for Laboratory Equipment

Choice of 3 Access Openings

A choice of 8, 10, and 12 inch (203, 254, and 305mm) work access openings that are NSF approved allow the user to configure their biosafety cabinet for their specific application while remaining confident of certified containment.

Choose from 3 access opening heights on a NU-543 Biosafety Cabinet.

Smooth Interior Option

The side and back walls made from one piece of steel already make routine wipe down easy. Go one step further and remove the work zone outlets and service valves to create the ultimate easy to clean steel surface appropriate for applications such as sterile drug compounding.

Biosafety Cabinet smooth interior for cleanability.

Specifications

LabGard NU-543 Class II, Type A2 Biosafety Cabinet
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls Optional with 8 or 10 inch (203 or 254mm) Work Access Openings
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior Optional
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Tempered
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.99% Efficiency on 0.3 microns
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 1/2 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 8, 10, 12-inch (203, 254, 305 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 70 (1778)
Est. Shipping Width Inches (mm) 46 (1168)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87.375 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93.375 (2371)
Exterior Width Inches (mm) 41 5/8 (1057)
Nominal Width Feet (Meters) 3 ft. (0.9m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 33 7/8 (860)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) Inquire
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) Inquire
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 34 3/8 (873)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.3
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening] 2.1
Electrical Configuration 115V60Hz
Junction Box Optional
Outlet Amps 3
Power Cord 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 10
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 55dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 320 (544)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 276-501 (649-851)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 387 (650)
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 341-554 (576-933)
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 269 (457)
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 255-450 (383-765)
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 903
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) Inquire
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) 826
Heat Rejected Vented (BTU/Hour) 120
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 460 lbs. / 209 kg.
Net Weight lbs (kg) 410 lbs. / 186 kg.
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right
Double Exhaust HEPA Filter Optional
Gas Supply Interlock with Blower N/A
Glass Sidewalls Optional
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Safety Glass
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 1/2 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 70 (1778)
Est. Shipping Width Inches (mm) 46 (1168)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 88 3/8 (2245)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 94 3/8 (2397)
Exterior Width Inches (mm) 41 5/8 (1057)
Nominal Width Feet (Meters) 3 ft. (0.9m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 33 7/8 (860)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 34 3/8 (873)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.3
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 230V5060Hz
Junction Box Optional
Outlet Amps 3
Power Cord 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 8
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 55dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 320 (544)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 276-501 (649-851)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 903
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 120
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method Optional
Performance Standard NSF-ANSI-49, EN-12469
Safety Certification
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 460 lbs. / 209 kg.
Net Weight lbs (kg) 410 lbs. / 186 kg.
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 1/2 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 49.2 (1250mm)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 41 5/8 (1057)
Nominal Width Feet (Meters) 3 ft. (0.9m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 33 7/8 (860)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 34 3/8 (873)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.3
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 100V5060Hz
Junction Box N/A
Outlet Amps 2
Power Cord 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 7
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 Inquire
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 320 (544)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 276-501 (649-851)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 903
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 120
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 460 lbs. / 209 kg.
Net Weight lbs (kg) 410 lbs. / 186 kg.
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 1/2 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 49.2 (1250mm)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 41 5/8 (1057)
Nominal Width Feet (Meters) 3 ft. (0.9m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 33 7/8 (860)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 34 3/8 (873)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.3
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 115V60Hz
Junction Box N/A
Outlet Amps 3
Power Cord 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 10
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 Inquire
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 320 (544)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 276-501 (649-851)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 903
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 120
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 460 (209)
Net Weight lbs (kg) 410 (186)
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter Optional
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 1/2 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 49.2 (1250mm)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 41 5/8 (1056)
Nominal Width Feet (Meters) 3 ft. (0.9m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 33 7/8 (860)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 34 3/8 (872)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.3
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 230V5060Hz
Junction Box N/A
Outlet Amps 3
Power Cord Single 12-foot (3.7m) 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 8
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 55dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 320 (544)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 276-501 (649-851)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 903
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 120
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1" (1.27-2.54)
Australian Test Method Optional
Performance Standard NSF-ANSI-49, EN-12469
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 460 (209)
Net Weight lbs (kg) 410 (186)
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls Optional with 8 or 10 inch (203 or 254mm) Work Access Openings
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior Optional
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Tempered
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.99% Efficiency on 0.3 microns
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 3/4 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 8, 10, 12-inch (203, 254, 305 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 70 (1778)
Est. Shipping Width Inches (mm) 58 (1473)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87.375 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93.375 (2371)
Exterior Width Inches (mm) 53 5/8 (1362)
Nominal Width Feet (Meters) 4 (1.2)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 45 7/8 (1165)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) Inquire
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) Inquire
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 46 3/8 (1178)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.9
Blower/Lights Amps [12-inch (305 mm) Access Opening] 3.2
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening] 2.6
Electrical Configuration 115V60Hz
Junction Box Optional
Outlet Amps 3
Power Cord 12 gauge - 3 Wire, 20A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 14
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 56 dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 426 (724)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 363-588 (617-1000)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 483 (821)
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 430-655 (731-1113)
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 359 (610)
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 295-520 (502-884)
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1140
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) 1256
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) 1020
Heat Rejected Vented (BTU/Hour) 157
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 530 lbs. / 240 kg.
Net Weight lbs (kg) 480 lbs. / 218 kg.
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right
Double Exhaust HEPA Filter Optional
Gas Supply Interlock with Blower N/A
Glass Sidewalls Optional
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Safety Glass
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 3/4 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 70 (1778)
Est. Shipping Width Inches (mm) 58 (1473)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 88 3/8 (2245)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 94 3/8 (2397)
Exterior Width Inches (mm) 53 5/8 (1362)
Nominal Width Feet (Meters) 4 ft. (1.2m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 45 7/8 (1165)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 46 3/8 (1178)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.9
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 230V5060Hz
Junction Box Optional
Outlet Amps 3
Power Cord 14 gauge - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 10
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 56 dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 426 (724)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 363-588 (617-1000)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1140
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 157
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method Optional
Performance Standard NSF-ANSI-49, EN-12469
Safety Certification
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 530 lbs. / 240 kg.
Net Weight lbs (kg) 480 lbs. / 218 kg.
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 3/4 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 57.1 (1450)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 53 5/8 (1362)
Nominal Width Feet (Meters) 4 ft. (1.2m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 45 7/8 (1165)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 46 3/8 (1178)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.9
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 100V5060Hz
Junction Box N/A
Outlet Amps 2
Power Cord 12 GA - 3 Wire, 20A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 11
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 Inquire
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 426 (724)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 363-588 (617-1000)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1140
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 157
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 530 (240)
Net Weight lbs (kg) 480 (218)
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 3/4 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 57.1 (1450)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 53 5/8 (1362)
Nominal Width Feet (Meters) 4 ft. (1.2m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 45 7/8 (1165)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 46 3/8 (1178)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.9
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 115V60Hz
Junction Box N/A
Outlet Amps 3
Power Cord 12 GA - 3 Wire, 20A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 14
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 Inquire
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 426 (724)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 363-588 (617-1000)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1140
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 157
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 530 (240)
Net Weight lbs (kg) 480 (218)
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter Optional
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 3/4 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 57.1 (1450)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 53 5/8 (1362)
Nominal Width Feet (Meters) 4 ft. (1.2m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 45 7/8 (1165)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 46 3/8 (1178)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 2.9
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 230V5060Hz
Junction Box N/A
Outlet Amps 3
Power Cord Single 12-foot (3.7m) 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 10
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 56dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 426 (724)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 363-588 (617-1000)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1140
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 157
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1" (1.27-2.54)
Australian Test Method Optional
Performance Standard NSF-ANSI-49, EN-12469
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 530 (240)
Net Weight lbs (kg) 480 (218)
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls Optional with 8 or 10 inch (203 or 254mm) Work Access Openings
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior Optional
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Tempered
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.99% Efficiency on 0.3 microns
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 8, 10, 12-inch (203, 254, 305 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 70 (1778)
Est. Shipping Width Inches (mm) 70 (1778)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87.375 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93.375 (2371)
Exterior Width Inches (mm) 65 5/8 (1669)
Nominal Width Feet (Meters) 5 ft. (1.5m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 57 7/8 (1470)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) Inquire
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) Inquire
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 46 3/8 (1178)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.5
Blower/Lights Amps [12-inch (305 mm) Access Opening] 4.8
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening] 4.1
Electrical Configuration 115V60Hz
Junction Box Optional
Outlet Amps 3
Power Cord 12 gauge - 3 Wire, 20A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 16
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 58
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 531 (902)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 451-676 (766-1149)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 610 (1036)
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 531-760 (909-1291)
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 445 (756)
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 365-590 (621-1003)
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1768
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) 1884
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) 1611
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 620 lbs. / 281 kg.
Net Weight lbs (kg) 570 lbs. / 258 kg.
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right
Double Exhaust HEPA Filter Optional
Gas Supply Interlock with Blower N/A
Glass Sidewalls Optional
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Safety Glass
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 70 (1778)
Est. Shipping Width Inches (mm) 70 (1778)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 88 3/8 (2245)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 94 3/8 (2397)
Exterior Width Inches (mm) 65 5/8 (1669)
Nominal Width Feet (Meters) 5 ft. (1.5m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 57 7/8 (1470)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 46 3/8 (1178)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.5
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 230V5060Hz
Junction Box Optional
Outlet Amps 3
Power Cord 14 gauge - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 11
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 58
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 531 (902)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 451-676 (766-1149)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1768
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method Optional
Performance Standard NSF-ANSI-49, EN-12469
Safety Certification
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 620 lbs. / 281 kg.
Net Weight lbs (kg) 570 lbs. / 258 kg.
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 74.8 (1900)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 65 5/8 (1669)
Nominal Width Feet (Meters) 5 ft. (1.5m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 57 7/8 (1470)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 58 3/8 (1483)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.5
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 100V5060Hz
Junction Box N/A
Outlet Amps 2
Power Cord 12 GA - 3 Wire, 20A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 13
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 Inquire
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 531 (902)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 451-676 (766-1149)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1768
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 620 (281)
Net Weight lbs (kg) 570 (258)
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 74.8 (1900)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 53 5/8 (1362)
Nominal Width Feet (Meters) 5 ft. (1.5m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 57 7/8 (1470)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 58 3/8 (1483)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.5
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 115V60Hz
Junction Box N/A
Outlet Amps 3
Power Cord 12 GA - 3 Wire, 20A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 16
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 Inquire
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 531 (902)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 451-676 (766-1149)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1768
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 620 (281)
Net Weight lbs (kg) 570 (258)
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter Optional
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 74.8 (1900)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 65 5/8 (1669)
Nominal Width Feet (Meters) 5 ft. (1.5m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 57 7/8 (1470)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 58 3/8 (1483)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.5
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 230V5060Hz
Junction Box N/A
Outlet Amps 3
Power Cord Single 12-foot (3.7m) 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 11
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 58 dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 531 (902)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 451-676 (766-1149)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1768
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1" (1.27-2.54)
Australian Test Method Optional
Performance Standard NSF-ANSI-49, EN-12469
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 620 (281)
Net Weight lbs (kg) 570 (258)
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls Optional with 8 or 10 inch (203 or 254mm) Work Access Openings
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior Optional
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Tempered
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.99% Efficiency on 0.3 microns
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 8, 10, 12-inch (203, 254, 305 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 70 (1778)
Est. Shipping Width Inches (mm) 82 (2083)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87.375 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93.375 (2371)
Exterior Width Inches (mm) 77 5/8 (1972)
Nominal Width Feet (Meters) 6 ft. (1.8m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 69 7/8 (1775)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) Inquire
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) Inquire
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 70 3/8 (1788)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.8
Blower/Lights Amps [12-inch (305 mm) Access Opening] 5.2
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening] 4.5
Electrical Configuration 115V60Hz
Junction Box Optional
Outlet Amps 3
Power Cord 12 gauge - 3 Wire, 20A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 16
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 60 dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 634 (1077)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 538-763 (915-1297)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 763 (1251)
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 634-865 (1088-1470)
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 532 (904)
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 436-661 (741-1124)
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1884
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) 2041
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) 1768
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 690 lbs. / 313 kg
Net Weight lbs (kg) 640 lbs. / 290 kg.
Blower Contact Wires Optional
Closure Panels Optional Rear Closure Panels for Seismic Brackets
Cord Pass Through Standard Right
Double Exhaust HEPA Filter Optional
Gas Supply Interlock with Blower N/A
Glass Sidewalls Optional
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing Optional 3/8" Soft Copper, 3/8" Black Pipe (Gas Only), or 1/2" Rigid Copper
Remote Service Valves N/A
Seismic Brackets or Studs Optional Rear or Floor Mount Seismic Brackets
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Three Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Three Each Side Wall Optional
Side Panels Optional with Plumbing out Bottom, Top or Back
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector Optional
Access Opening Glass Type Safety Glass
Armrest Standard Plastic with Optional Stainless Steel
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Single Piece Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 43 (1092)
Est. Shipping Height Inches (mm) 70 (1778)
Est. Shipping Width Inches (mm) 82 (2083)
Exterior Depth Inches (mm) 32 1/8 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 88 3/8 (2245)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 94 3/8 (2397)
Exterior Width Inches (mm) 77 5/8 (1972)
Nominal Width Feet (Meters) 6 ft. (1.8m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 69 7/8 (1775)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 70 3/8 (1788)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.8
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 230V5060Hz
Junction Box Optional
Outlet Amps 3
Power Cord 14 gauge - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 11
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 60 dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 634 (1077)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 538-763 (915-1297)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1884
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method Optional
Performance Standard NSF-ANSI-49, EN-12469
Safety Certification
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 690 lbs. / 313 kg
Net Weight lbs (kg) 640 lbs. / 290 kg.
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 80.3 (2040)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 77 5/8 (1972)
Nominal Width Feet (Meters) 6 ft. (1.8m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 69 7/8 (1775)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 70 3/8 (1788)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.8
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 100V5060Hz
Junction Box N/A
Outlet Amps 2
Power Cord 12 GA - 3 Wire, 20A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 13
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 Inquire
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 634 (1077)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 538-763 (915-1297)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1884
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 690 (313)
Net Weight lbs (kg) 640 (290)
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter N/A
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 80.3 (2040)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 77 5/8 (1972)
Nominal Width Feet (Meters) 6 ft. (1.8m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 69 7/8 (1775)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 70 3/8 (1788)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.8
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 100V5060Hz
Junction Box N/A
Outlet Amps 3
Power Cord 12 GA - 3 Wire, 20A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 16
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 Inquire
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 634 (1077)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 538-763 (915-1297)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1884
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1"/1.27-2.54mm H2O
Australian Test Method N/A
Performance Standard NSF-ANSI-49
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 690 (313)
Net Weight lbs (kg) 640 (290)
Blower Contact Wires N/A
Closure Panels N/A
Cord Pass Through Standard Right
Double Exhaust HEPA Filter Optional
Gas Supply Interlock with Blower N/A
Glass Sidewalls N/A
IV Bar with 6 Hooks Optional
Magnifying Glass in Window N/A
Motorized Base Stand Optional as Separate Accessory
Motorized Window N/A
Other Built-in Supply Filter Option(s) N/A
Outlet(s) Standard, two backwall
Plumbing N/A
Remote Service Valves N/A
Seismic Brackets or Studs N/A
Service Couplings (3/8-inch NPT) Two Couplings on Left Side Wall and One on Right Side Wall are Standard, Maximum of Two Each Side Wall Optional
Service Valves (3/8-inch NPT) One Valve on Right Side Wall is Standard, Maximum of Two Each Side Wall Optional
Side Panels N/A
Smooth Interior N/A
Ultraviolet (UV) Light Optional
Window Edge Protector N/A
Access Opening Glass Type Safety Glass
Armrest Plastic
Cabinet Construction All welded stainless steel 16/18 GA, Type 304 pressure tight design
Casters N/A
Decontamination Seal-able Window N/A
Diffuser Metal, non-flammable
Drain Valve Location Front right
Exhaust Filter 11 1/2-inch (292 mm) 99.995% Efficiency @ MPPS
Front & Control Panel Material Painted Steel
HEPA Filter Seal Type HEPEX Zero Leak Neoprene Seal, Spring-loaded
Lighting LED
Main Cabinet Wrap Seam Welded Stainless Steel Side and Back Wall Construction
Motor(s) 1 HP DC ECM
Plenum Type HEPEX
Pre-filter N/A
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.995% Efficiency @ MPPS
Viewing Window Inches (mm) 21 (533) open to fully closed
Work Access Opening(s) 10-inch (254 mm)
Work Surface One-Piece Dished Stainless Steel with Prop-Up Rod
Work Zone Wrap Single Piece Stainless Steel Side and Back Wall Construction
Data Output Features RS-232
Remote Alarm Terminals Standard
Est. Shipping Depth Inches (mm) 41.3 (1050mm)
Est. Shipping Height Inches (mm) 76.8 (1950mm)
Est. Shipping Width Inches (mm) 80.3 (2040)
Exterior Depth Inches (mm) 32 3/16 (817)
Exterior Depth with Armrest Removed Inches (mm) 31 7/16 (799)
Exterior Height (Minimum for Transport) Inches (mm) 59 (1499)
Exterior Height Inches (mm) 60 7/8 (1546)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 87 3/8 (2219)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 93 3/8 (2372)
Exterior Width Inches (mm) 77 5/8 (1972)
Nominal Width Feet (Meters) 6 ft. (1.8m)
Useable Work Tray Area Depth Inches (mm) 20 7/8 (530)
Useable Work Tray Area Width Inches (mm) 69 7/8 (1775)
Work Area Depth Measured at 10-inches (254 mm) Window Height Inches (mm) 25 3/4 (654)
Work Area Depth Measured at 12-inches (305 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 14-inches (356 mm) Window Height Inches (mm) N/A
Work Area Depth Measured at 8-inches (203 mm) Window Height Inches (mm) N/A
Work Area Height Inches (mm) 28 1/2 (724)
Work Area Width Inches (mm) 70 3/8 (1788)
Blower/Lights Amps [10-inch (254 mm) Access Opening] 4.8
Blower/Lights Amps [12-inch (305 mm) Access Opening]
Blower/Lights Amps [14-inch (356mm) Access Opening]
Blower/Lights Amps [8-inch (203 mm) Access Opening]
Electrical Configuration 230V5060Hz
Junction Box N/A
Outlet Amps 3
Power Cord Single 12-foot (3.7m) 14 GA - 3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Rated Amps 11
Light Intensity fc (Lux) 90-120 (968-1291)
Reach into workzone Inches (mm) 6 (152)
Sound Pressure Level per ISO 4871 ≤ 60 dba
10-inch (254 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) 634 (1077)
10-inch (254 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) 538-763 (915-1297)
12-inch (305 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
12-inch (305 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Fixed Canopy (NU-926) CFM(CMH) N/A
14-inch (356mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM(CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Fixed Canopy (NU-907/NU-916) CFM (CMH) N/A
8-inch (203 mm) Opening Exhaust Requirement for Variable Flow Canopy (NU-911) CFM (CMH) N/A
Bag In Bag Out N/A
Heat Rejected 10-inch (254 mm) Access Opening (BTU/Hour) 1884
Heat Rejected 12-inch (305 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 14-inch (356 mm) Access Opening (BTU/Hour) N/A
Heat Rejected 8-inch (203 mm) Access Opening (BTU/Hour) N/A
Heat Rejected Vented (BTU/Hour) 198
Other Built-in Exhaust Option(s) N/A
Plant Duct Static Pressure Inches (mm) 0.05-0.1" (1.27-2.54)
Australian Test Method Optional
Performance Standard NSF-ANSI-49, EN-12469
Safety Certification UL, UL-C
Air Cleanliness (ISO 14644) ISO-Class-5
Downflow fpm (m/s) 60 fpm (0.30 m/s)
Fumigation: per NIH/NSF Procedures True
Inflow fpm (m/s) 105 fpm (0.53 m/s)
Protection Product, Personnel, Environmental
Airflow Monitor SingleAirflowSensor
Control System FlowGard
Est. Shipping Weight lbs (kg) 690 (313)
Net Weight lbs (kg) 640 (290)

Review

Resources

Options

  • 10 Inch Safety Plate Glass Sliding Window With Glass Sidewalls
  • 10 Inch Tempered Glass Sliding Window With Glass Sidewalls
  • 10" (254 mm) Access Opening Sliding Safety Plate Glass Window, NSF Approved Cord Pass Through (Right Sidewall)
  • 10" (254 mm) Access Opening Tempered Sliding Glass, NSF Approved Cord Pass Through (Right Sidewall)
  • 12" (305 mm) Access Opening Sliding Tempered Glass Window, NSF Approved Cord Pass Through (Right Sidewall)
  • 8 Inch Safety Plate Glass Sliding Window With Glass Sidewalls
  • 8 Inch Tempered Glass Sliding Window With Glass Sidewalls
  • 8" (203 mm) Access Opening Sliding Safety Plate Glass Window, NSF Approved Cord Pass Through (Right Sidewall)
  • 8" (203 mm) Access Opening Tempered Sliding Glass, NSF Approved Cord Pass Through Right Side
  • Smooth Interior With 10 Inch Window And Right Side Pass-Through
  • Smooth Interior With 12 Inch Window And Right Side Pass-Through
  • Smooth Interior With 8 Inch Window And Right Side Pass-Through
  • Plastic Armrest
  • Stainless Steel Armrest
  • 12-inch (305 mm) Metal Frame Exhaust Separatorless HEPA Filter 99.99% efficient @ 0.3 µ with Permanent Plenum
  • Double Metal Frame Exhaust Filter
  • Metal Frame Exhaust Filter
  • Metal Frame H14 Exhaust Filter 99.995% @ MPPS
  • IV BAR W/6 HOOKS 3'
  • IV BAR W/6 HOOKS 4'
  • IV BAR W/6 HOOKS 5'
  • AUSTRALIAN TEST METHOD
  • Blower Contact Wires
  • IV Bar With 6 Hooks
  • Left Sidewall NSF Cord Pass-Through
  • Stainless Steel Window Edge Protector
  • 115V 15 Amp Outlet (Type B)
  • 15 Amp South African Outlet (Type M)
  • 230V US Standard Outlet (Type B)
  • 5 Amp Duplex Outlet With GFI Option
  • 5 Amp Old UK Outlet (Type D)
  • Australian Outlet (Type I)
  • Current UK Outlet (Type G)
  • Danish Outlet (Type K)
  • Dedicated 15 Amp Power Cord
  • Dedicated 15 Amp Power Cord With Gfi Option
  • Dedicated 20 Amp Power Cord
  • Dedicated 20 Amp Power Cord With Gfi Option
  • Israel Outlet (Type H)
  • OUTLET - AUSTRALIAN
  • Outlet - China Type I (Qty 2) (Backwall) (230V)
  • OUTLET - CURRENT UK TYPE G
  • OUTLET - SCHUKO
  • OUTLET - US
  • Outlet Type E (Qty 2)
  • Schuko Outlet (Type F)
  • Swiss Outlet (Type J)
  • Two Outlets - 1 Standard And 1 GFI
  • 3/8" Black Pipe
  • 3/8" Rigid Copper
  • 3/8" Soft Copper
  • 115V 60Hz 15 Amp Power Input
  • 115V 60Hz 20 Amp Power Cord
  • 230V Power Cord
  • Junction Box
  • Power Cord 115V 60Hz 15A
  • Power Cord 115V 60Hz 20A
  • Power Cord 230V
  • DOUBLE METAL FR EXHAUST FILTER
  • 31 Inch Seismic Floor Brackets
  • Rear Mount Seismic Brackets For Adjustable Basestand
  • Rear Mount Seismic Brackets For Fixed Height Basestand
  • Side Mount Seismic Brackets For Adjustable Basestand
  • Side Mount Seismic Brackets For Telescoping Basestand
  • Bottom Left Plugged Coupling
  • Bottom Right Plugged Coupling
  • Middle Left Plugged Coupling
  • Middle Right Plugged Coupling
  • Service Coupling Left Bottom
  • Service Coupling Left Middle
  • Service Coupling Right Bottom
  • Service Coupling Right Middle
  • Top Left Plugged Coupling
  • Top Right Plugged Coupling
  • Bottom Left Service Valve
  • Bottom Right Service Valve
  • Middle Left Service Valve
  • Middle Right Service Valve
  • SERVICE VALVE LEFT BOTTOM
  • SERVICE VALVE LEFT MIDDLE
  • Service Valve Right Bottom
  • SERVICE VALVE RIGHT MIDDLE
  • Top Left Service Valve
  • Top Right Service Valve
  • Side Panels w/o Plumbing NSF Cord Pass Thru Compatible
  • Side Panels w/Plumbing out Back NSF Cord Pass Thru Compatible
  • Side Panels w/Plumbing out Bottom NSF Cord Pass Thru Compatible
  • Side Panels w/Plumbing out Top NSF Cord Pass Thru Compatible
  • Without Side Panels
  • 3-inch (76 mm) Metal Frame Supply Separatorless HEPA Filter 99.99% efficient @ 0.3 µ with Permanent Plenum
  • 99.995% Metal Frame Supply Filter
  • Metal Frame H14 Supply Filter 99.995% @ MPPS
  • 115V Ultraviolet Light
  • 230V Ultraviolet Light
  • ULTRAVIOLET LIGHT 230V
  • Without Ultraviolet (UV) Light

Request Your Quote for a NU-543

Please fill out the form below for a lab equipment quote and we'll get to work on getting you what you need. Need to talk with someone right away? Give us a call at 763-553-1270.

Thank you for completing the form.

We will be in touch. If you have any urgent questions, please reach out at 763-553-1270.