Blizzard HC NU-99578J -80°C Ultralow Freezer
Engineered for secure long-term storage, the Blizzard NU-99578J delivers stable -86 °C performance, uniform temperatures, and energy-efficient HC cooling to protect valuable research and clinical samples.
- Overview
- Specifications
- Reviews
- Resources
- Options
Overview
The Blizzard NU-99578J -86 °C Ultralow Temperature Freezer provides 20.6 cu. ft. (582 L) of validated cold storage engineered for the long-term preservation of cell lines, tissues, vaccines, and high-value research samples. Built for life science, biomedical, and clinical environments, it delivers exceptionally tight temperature uniformity and stable -86 °C performance to help ensure the viability of irreplaceable materials.
A durable multi-gasket outer door and insulated inner doors minimize frost intrusion and maintain thermal integrity during routine access. The Electronic Control Center supports continuous temperature monitoring with clear digital readouts, event logs, and audible/visual alarms that alert staff to deviations. During a power interruption, an integrated battery backup preserves monitoring and alarm functions, while optional CO₂ or LN₂ emergency cooling provides added protection for mission-critical samples.
Using energy-efficient hydrocarbon (HC) refrigerants, the NU-99578J achieves rapid recovery and reduced energy consumption without sacrificing performance—supporting sustainability goals and lowering operating costs. Its intuitive interface, ergonomic door design, and reliable uptime make it an excellent fit for high-throughput labs that prioritize sample security, workflow efficiency, and compliance with internal quality standards.
Designed for dependable performance in demanding research environments, the Blizzard NU-99578J combines precision, protection, and ease of use to give your team confidence in every storage cycle.
Exceptional Temperature Stability and Uniformity
Advanced Cooling Technology
Robust Design with Enhanced Insulation Features
User-Friendly Interface
Enhanced Safety Features
Specifications
| 2-inch Box Capacity | 400 |
| Rack Capacity | 16 |
| Access Port Location | Back Wall |
| Back Up Battery for Alarm Functions | High/low temperature, power failure, door open, sensor failure, high ambient temperature, hot condenser and low battery alarms |
| Cabinet Thickness Inches (mm) | 3.5 (90) |
| Casters | All-direction caster with fixing stand |
| Door Thickness Inches (mm) | 3.5 (90) |
| Exterior Door | Single Door |
| Exterior Door Seal | Quadruple Seal on the Outside Door |
| Exterior Material | Color Coating Cold Plate Steel |
| Fan Brand | EBM |
| Inner Doors | 4 |
| Insulation | VIP+CFC Free Foaming Agent |
| Interior Door Seal | Single Seal on all Interior Doors |
| Interior Material | Color Coating Electric Zinc Steel Plate |
| Leg Levelers | 2 |
| Locking Mechanism | Key |
| Shelf Capacity lbs (kg) | 177 (80) |
| Shelf Material | Stainless Steel |
| Shelves | 3 Adjustable, 4 Locations |
| Style | Upright |
| Adjustable High/Low Temperature Alarms | True |
| Alarms | Temperature, Power Failure, Probe Failure, Condenser, Ambient Temperature, Door Ajar, Low Battery, etc. |
| Auto Voltage Safeguard | Included |
| Data Output Features | USB, RS-232/485 |
| Power Switch | On-Off with Circuit Breaker |
| Remote Alarm Terminals | Remote Alarm Port, RS232 / RS485 (Optional) |
| Setpoint Security | Yes |
| Est. Shipping Depth Inches (mm) | 41 (1041) |
| Est. Shipping Height Inches (mm) | 84 (2137) |
| Est. Shipping Width Inches (mm) | 37 (940) |
| Exterior Depth Inches (mm) | 38.6 (980) |
| Exterior Depth with Door Open Inches (mm) | 69 (1754) |
| Exterior Height Inches (mm) | 78 (1980) |
| Exterior Width Inches (mm) | 35.4 (895) |
| Footprint Depth inches (mm) | 38.6 (980) |
| Footprint Width inches (mm) | 35.4 (895) |
| Interior Depth Inches (mm) | 28.2 (716) |
| Interior Height Inches (mm) | 51.6 (1310) |
| Interior Volume Cubic Feet (Liters) | 20.4 (578) |
| Interior Width Inches (mm) | 24.4 (620) |
| Shelf Depth Inches (mm) | 26.6 (677) |
| Shelf Width Inches (mm) | 23.75 (604) |
| Electrical Configuration | 230V50Hz |
| Input Power (W) | 1540 |
| Power Consumption KWh/day | 8.5 |
| Power Cord | Grounded Three Prong Power Plug, Rated 16A |
| Power Cord Length Foot (Meter) | 8.2 ft (2.5m) |
| Rated Current (A) | 9.0 |
| Rated Frequency (Hz) | 50 |
| Rated Voltage (V) | 230 |
| Stable Current (A) | 7 |
| Sound Level | 50 dB(A) |
| 1 Minutes Door Open Recovery Time (25°C ambient running temp -75°C) in Minutes | 30 |
| Cool Down Time (25°C ambient to -80°C) in Minutes | 270 |
| Heat Rejected (BTU/Hour) | 1333 |
| Warm-Up Time (25°C ambient -80°C to -50°C) in Minutes | 260 |
| Compressor Capacity Watt | 950 |
| Compressor Type/Brand/Number | Hermetic Reciprocating Type / SECOP / 2 |
| Condenser Type | Enhanced Micro-Channel & Forced-Air Cooled |
| Defrost Method | Manual |
| Evaporator Type | Cold Wall With Enhanced Heat Transfer Treatment |
| Refrigerant Charge/Flammable | R290 in 1st Stage / R290 + R170 Mix in 2nd Stage / Flammable in JE Version; R290 in 1st Stage / R170 in 2nd Stage / Flammable in JG Version |
| Refrigeration System Type | Direct Cooling |
| Ambient Temperature (°C) | 10 to 32 |
| Temperature Accuracy °C | ±1 |
| Temperature Control | Microprocessor Controller |
| Temperature Range °C | -40 to -86 |
| Temperature Sensor Type | RTD (Pt100) |
| Temperature Uniformity °C | ±5 |
| Est. Shipping Weight lbs (kg) | Estimated 727 lbs (330 kgs) |
| Net Weight lbs (kg) | 661 lbs (300 kg) |
| 2-inch Box Capacity | 400 |
| Rack Capacity | 16 |
| Access Port Location | Back Wall |
| Back Up Battery for Alarm Functions | High/low temperature, power failure, door open, sensor failure, high ambient temperature, hot condenser and low battery alarms |
| Cabinet Thickness Inches (mm) | 3.5 (90) |
| Casters | All-direction caster with fixing stand |
| Door Thickness Inches (mm) | 3.5 (90) |
| Exterior Door | Single Door |
| Exterior Door Seal | Quadruple Seal on the Outside Door |
| Exterior Material | Color Coating Cold Plate Steel |
| Fan Brand | EBM |
| Inner Doors | 4 |
| Insulation | VIP+CFC Free Foaming Agent |
| Interior Door Seal | Single Seal on all Interior Doors |
| Interior Material | Color Coating Electric Zinc Steel Plate |
| Leg Levelers | 2 |
| Locking Mechanism | Key |
| Shelf Capacity lbs (kg) | 177 (80) |
| Shelf Material | Stainless Steel |
| Shelves | 3 Adjustable, 4 Locations |
| Style | Upright |
| Adjustable High/Low Temperature Alarms | True |
| Alarms | Temperature, Power Failure, Probe Failure, Condenser, Ambient Temperature, Door Ajar, Low Battery, etc. |
| Auto Voltage Safeguard | Included |
| Data Output Features | USB, RS-232/485 |
| Power Switch | On-Off with Circuit Breaker |
| Remote Alarm Terminals | Remote Alarm Port, RS232 / RS485 (Optional) |
| Setpoint Security | Yes |
| Est. Shipping Depth Inches (mm) | 41 (1041) |
| Est. Shipping Height Inches (mm) | 84 (2137) |
| Est. Shipping Width Inches (mm) | 37 (940) |
| Exterior Depth Inches (mm) | 38.6 (980) |
| Exterior Depth with Door Open Inches (mm) | 69 (1754) |
| Exterior Height Inches (mm) | 78 (1980) |
| Exterior Width Inches (mm) | 35.4 (895) |
| Footprint Depth inches (mm) | 38.6 (980) |
| Footprint Width inches (mm) | 35.4 (895) |
| Interior Depth Inches (mm) | 28.2 (716) |
| Interior Height Inches (mm) | 51.6 (1310) |
| Interior Volume Cubic Feet (Liters) | 20.4 (578) |
| Interior Width Inches (mm) | 24.4 (620) |
| Shelf Depth Inches (mm) | 26.6 (677) |
| Shelf Width Inches (mm) | 23.75 (604) |
| Electrical Configuration | 220V60Hz |
| Input Power (W) | 1540 |
| Power Consumption KWh/day | 8.5 |
| Power Cord | Grounded Three Prong Power Plug, Rated 16A |
| Power Cord Length Foot (Meter) | 8.2 ft (2.5m) |
| Rated Current (A) | 9.0 |
| Rated Frequency (Hz) | 60 |
| Rated Voltage (V) | 220 |
| Stable Current (A) | 7 |
| Sound Level | 50 dB(A) |
| 1 Minutes Door Open Recovery Time (25°C ambient running temp -75°C) in Minutes | 30 |
| Cool Down Time (25°C ambient to -80°C) in Minutes | 270 |
| Heat Rejected (BTU/Hour) | 1208 |
| Warm-Up Time (25°C ambient -80°C to -50°C) in Minutes | 260 |
| Compressor Capacity Watt | 950 |
| Compressor Type/Brand/Number | Hermetic Reciprocating Type / SECOP / 2 |
| Condenser Type | Enhanced Micro-Channel & Forced-Air Cooled |
| Defrost Method | Manual |
| Evaporator Type | Cold Wall With Enhanced Heat Transfer Treatment |
| Refrigerant Charge/Flammable | R290 in 1st Stage / R290 + R170 Mix in 2nd Stage / Flammable in JE Version; R290 in 1st Stage / R170 in 2nd Stage / Flammable in JG Version |
| Refrigeration System Type | Direct Cooling |
| Ambient Temperature (°C) | 10 to 32 |
| Temperature Accuracy °C | ±1 |
| Temperature Control | Microprocessor Controller |
| Temperature Range °C | -40 to -86 |
| Temperature Sensor Type | RTD (Pt100) |
| Temperature Uniformity °C | ±5 |
| Est. Shipping Weight lbs (kg) | Estimated 727 lbs (330 kgs) |
| Net Weight lbs (kg) | 661 lbs (300 kg) |
| 2-inch Box Capacity | 400 |
| Rack Capacity | 16 |
| Access Port Location | Back Wall |
| Back Up Battery for Alarm Functions | High/low temperature, power failure, door open, sensor failure, high ambient temperature, hot condenser and low battery alarms |
| Cabinet Thickness Inches (mm) | 3.5 (90) |
| Casters | All-direction caster with fixing stand |
| Door Thickness Inches (mm) | 3.5 (90) |
| Exterior Door | Single Door |
| Exterior Door Seal | Quadruple Seal on the Outside Door |
| Exterior Material | Color Coating Cold Plate Steel |
| Fan Brand | EBM |
| Inner Doors | 4 |
| Insulation | VIP+CFC Free Foaming Agent |
| Interior Door Seal | Single Seal on all Interior Doors |
| Interior Material | Color Coating Electric Zinc Steel Plate |
| Leg Levelers | 2 |
| Locking Mechanism | Key |
| Shelf Capacity lbs (kg) | 177 (80) |
| Shelf Material | Stainless Steel |
| Shelves | 3 Adjustable, 4 Locations |
| Style | Upright |
| Adjustable High/Low Temperature Alarms | True |
| Alarms | Temperature, Power Failure, Probe Failure, Condenser, Ambient Temperature, Door Ajar, Low Battery, etc. |
| Auto Voltage Safeguard | Included |
| Data Output Features | USB, RS-232/485 |
| Power Switch | On-Off with Circuit Breaker |
| Remote Alarm Terminals | Remote Alarm Port, RS232 / RS485 (Optional) |
| Setpoint Security | Yes |
| Est. Shipping Depth Inches (mm) | 41 (1041) |
| Est. Shipping Height Inches (mm) | 84 (2137) |
| Est. Shipping Width Inches (mm) | 37 (940) |
| Exterior Depth Inches (mm) | 38.6 (980) |
| Exterior Depth with Door Open Inches (mm) | 69 (1754) |
| Exterior Height Inches (mm) | 78 (1980) |
| Exterior Width Inches (mm) | 35.4 (895) |
| Footprint Depth inches (mm) | 38.6 (980) |
| Footprint Width inches (mm) | 35.4 (895) |
| Interior Depth Inches (mm) | 28.2 (716) |
| Interior Height Inches (mm) | 51.6 (1310) |
| Interior Volume Cubic Feet (Liters) | 20.4 (578) |
| Interior Width Inches (mm) | 24.4 (620) |
| Shelf Depth Inches (mm) | 26.6 (677) |
| Shelf Width Inches (mm) | 23.75 (604) |
| Electrical Configuration | 115V60Hz |
| Input Power (W) | 935 |
| Power Consumption KWh/day | 8.5 |
| Power Cord | Grounded Three Prong Power Plug, Rated 20A |
| Power Cord Length Foot (Meter) | 8.2 ft (2.5m) |
| Rated Current (A) | 18.0 |
| Rated Frequency (Hz) | 60 |
| Rated Voltage (V) | 115 |
| Stable Current (A) | 8.1 |
| Sound Level | 50 dB(A) |
| 1 Minutes Door Open Recovery Time (25°C ambient running temp -75°C) in Minutes | 30 |
| Cool Down Time (25°C ambient to -80°C) in Minutes | 270 |
| Heat Rejected (BTU/Hour) | 1133 |
| Warm-Up Time (25°C ambient -80°C to -50°C) in Minutes | 260 |
| Compressor Capacity Watt | 950 |
| Compressor Type/Brand/Number | Hermetic Reciprocating Type / SECOP / 2 |
| Condenser Type | Enhanced Micro-Channel & Forced-Air Cooled |
| Defrost Method | Manual |
| Evaporator Type | Cold Wall With Enhanced Heat Transfer Treatment |
| Refrigerant Charge/Flammable | R290 in 1st Stage / R290 + R170 Mix in 2nd Stage / Flammable in JE Version; R290 in 1st Stage / R170 in 2nd Stage / Flammable in JG Version |
| Refrigeration System Type | Direct Cooling |
| Ambient Temperature (°C) | 10 to 32 |
| Temperature Accuracy °C | ±1 |
| Temperature Control | Microprocessor Controller |
| Temperature Range °C | -40 to -86 |
| Temperature Sensor Type | RTD (Pt100) |
| Temperature Uniformity °C | ±5 |
| Est. Shipping Weight lbs (kg) | Estimated 727 lbs (330 kgs) |
| Net Weight lbs (kg) | 661 lbs (300 kg) |