More Views

LabGard TE (Total Exhaust) NU-560 Class II, Type B2 Biosafety Cabinet

NU-560 Total Exhaust Biological Safety Cabinet (BSC) may be used for work with non-flammable, non-explosive volatile chemicals and radionuclides by providing personnel, product, and environmental protection by exhausting 100% of contaminated air. LabGard® ES offers economical operation through the use of an ultra-high efficiency motor to maximize filter life and monolithic silicone-free construction for long product life all for an affordable price.


NSF/ANSI 49   UL Canada United States Listing

Part #: NU-560

Features

Safety

Exhaust Interlock

Model NU-560 features an exhaust interlock system that prevents operation of the internal supply blower unless the exhaust flow is sufficient to provide the correct air barrier inflow velocity at startup.


100% Total Exhaust

LabGard TE is a Total Exhaust Class II, Type B2 Biosafety Cabinet exhausting 100% of airflow through a facility’s HVAC system.


Technology

TouchLink Electronic Control System (ECS)

The TouchLink ECS is a color touch screen providing simple operation of cabinet functions.

  • Control blower DC ECM Motor via solid-state DC Motor Controller that provides automatic compensation (constant volume control) for both filter loading and line voltage variances.
  • Intelliflow™ - Fast, accurate, reliable dual thermistor, airflow sensors and digital differential velocity pressure flow grid powered by TSI to control and monitor cabinet airflows to set points.
  • Control lights via solid state switch.
  • Control outlets via solid state switch.
  • Display date/time w/battery backup.
  • Display alarm set points high/low for error conditions (downflow/inflow).
  • Display complete calibration, option menu and diagnostic functions.
  • Security password protection of cabinet use.
  • Night setback mode. Used to reduce exhaust volume during non-use times. Allows Building Automation System (BAS) contact closure input for cabinet indication of night setback mode.
  • Autorun timer allows the cabinet to turn on and off on a daily basis automatically.
  • Timer/Interlock functions for fluorescent light, outlet, and ultraviolet light.

Ultra-High Efficiency Motor

A single ultra-high efficiency motor with optimally determine forward curved fan uses less energy to operate while containing more torque to extend the life of your HEPA filters.


LED Lighting

Externally mounted, energy-efficient LED lighting provides 80 to 150 foot-candles (860 to 1600 LUX) on work surface.


Ergonomics

LabGard TE is ergonomically designed for maximum user comfort and adjustability to meet the requirements of the American Disabilities Act (ADA.)

  • Heavy-duty plastic armrest incorporating a large 2 inch (51mm) forearm support area with 1/2 inch (12mm) recessed front grill, designed for armrest comfort while maintaining containment performance.
  • Maximum visibility into cabinet work zone shall be at least 20-1/2 inches (521mm) from front access airfoil to exterior light housing.
  • Model NU-560 features a centrally located instrument panel within the control center that is easily serviced with quick disconnects.
  • The capability of incorporating a user-adjustable base stand or base storage cabinet as an option.
  • The cabinet features a smooth operating sliding window from 1.125 inches (29mm) closed to the full opening at 18-1/2 inches (470mm).
  • Cabinet offers a large work tray (20 3/4 inch (527mm) depth) removable with coved corners for easy cleaning.
  • NU-560 provides a 10-degree slope front window for enhanced user comfort.

Construction

Single Piece Monolithic Cabinet Shell

At the core of any LabGard BSC is the cabinet’s shell. Robust sheets of stainless steel are bent, folded, and seam welded to create a pressure tight, a monolithic design minimizing the use of sealants.


Coved Interior Work Zone

A single piece of stainless steel is bent to create the interior work zone providing coved interior corners for easy cleaning.


Standard Features

  • 8-Inch (203 mm) Access Opening Tempered Sliding Glass
  • Metal Frame Supply HEPA Filter 99.99% @ 0.3 Micron
  • Metal Frame Exhaust HEPA Filter 99.99% @ 0.3 Micron
  • Standard Outlet Left Front Faring, Outlet Plate Cover Right Front Faring
  • Right Middle Service Coupling
  • Right Bottom Service Valve
  • Left Middle Service Coupling
  • Left Bottom Service Coupling
  • Monolithic 16/18 GA Stainless Steel Interior and Exterior Construction
  • Recessed and Removable Front Intake Grill
  • Heavy Duty Ergonomic Plastic Armrest
  • 3/16” Diameter Stainless Steel Mesh Accessible Paper Catch
  • 100% Front Maintenance Construction
  • 250% Filter Load Capacity
  • 10° Sliding View Window
  • TouchLink Control System w/ Intelliflow Airflow Probe
  • Ultra-high Efficiency DC/ECM Motor
  • Ultra-high Efficiency LED Lighting
  • Certification Value Exhaust Requirement: 740 CFM @ 1.7” w.g.
  • Concurrent Value Exhaust Requirement: 815 CFM @ 1.7” w.g.
  • Power Cord

Warranty

5 Years Parts and Labor including Supply HEPA filter (United States and Canada)

6 Years Parts including Supply HEPA filter (International)


Options

Access Opening

560(Size)M443 8-Inch (203 mm) Access Opening Tempered Sliding Glass

Supply Filter

560(Size)M416 Metal Frame Supply HEPA Filter 99.99% @ 0.3 Micron

Exhaust Filter

560(Size)M417 Metal Frame Exhaust HEPA Filter 99.99% @ 0.3 Micron

Bag-in Bag-Out Filter

560(Size)M295 Bag-in/Bag-out Exhaust HEPA Filter
560(Size)M345 No Bag-in/Bag-out Exhaust HEPA Filter

Power Inputs

560E07 Junction Box
560E60 Power Cord (115V) (15 Amp)

UV Light

560(Size)E34 Ultraviolet (UV) Light (115V)
560(Size)E61 No Ultraviolet (UV) Light (115V)

Armrest

560(Size)M211 Stainless Steel Armrest
560(Size)M324 Heavy Duty Ergonomic Plastic Armrest

Airflow Control

560E47 Exhaust Airflow Loss Override
560E48 Cabinet Off Override
560E49 Air Supply On/Off Control (100V/115V)
560E50 Delay On Supply Airflow (100V/115V)
560E51 Delay Off Exhaust Airflow

Other

430M427 NSF Cord Pass-Thru Right Side Wall
430M428 NSF Cord Pass-Thru Left Side Wall
560(Size)M262 IV Bar with 6 Hooks, 3 Height Locations
560(Size)M387 Prop-Up Work Surface Tray
560(Size)M411 Stainless Steel Window Sash Edge Protector

Outlets

560E02 GFI Type B Outlet (3 amp max) (Qty 1) (Left Front Faring) (115V)
560E05 15 Amp Type B Outlet (3 amp max) (Qty 2) (Right & Left Front Farring) (115V)
560E59 15 Amp Type B Outlet (3 amp max) (Qty 1) (Left Front Farring) (115V)
560E68 Outlet Cover Plate (Right Front Faring)

Side Panels

560M334 No Side Panels
560M284 Side Panel without Plumbing (Qty 2)
560M237 Side Panel w/ Plumbing Out Bottom (Qty 2)
560M238 Side Panel w/ Plumbing Out Top (Qty 2)
560M239 Side Panel w/ Plumbing Out Back (Qty 2)

Plumbing

560M120 3/8" Soft Copper Pipe
560M121 3/8" Black Pipe
560M122 1/2" Rigid Copper Pipe

Service Valves

560M193 Left Top Service Valve
560M194 Left Middle Service Valve
560M195 Left Bottom Service Valve
560M196 Right Top Service Valve
560M197 Right Middle Service Valve
560M198 Right Bottom Service Valve

Remote Controlled Service Valves

560M199 Left Top Remote Control Service Valve
560M200 Left Middle Remote Control Service Valve
560M201 Left Bottom Remote Control Service Valve
560M202 Right Top Remote Control Service Valve
560M203 Right Middle Remote Control Service Valve
560M204 Right Bottom Remote Control Service Valve

Service Couplings

560M205 Left Top Service Coupling
560M206 Left Middle Service Coupling
560M207 Left Bottom Service Coupling
560M208 Right Top Service Coupling
560M209 Right Middle Service Coupling
560M285 Right Bottom Service Coupling

Seismic

560(Size)M264 Seismic Brackets
560(Size)M306 Seismic Brackets for Adjustable Bast Stand

IQ/PQ/CQ

NU-560-3Q IQ/PQ/CQ Document Binder
Specs

Catalog Number

NU-560-400
Nominal 4 foot (1.2m)

NU-560-600
Nominal 6 foot (1.8m)

Performance Specifications

1.  Personal Protection

2.  Product Protection

NSF/ANSI 49 NSF/ANSI 49
NSF Std. No. 49 Class Class II, Type B2 Class II, Type B2
Style of Cabinet Bench Top/Console w/Base Stand/
Storage Cabinet
Bench Top/Console w/Base Stand/
Storage Cabinet
Cabinet Construction All Welded Stainless Steel 16GA,
Type 304 Pressure Tight Design
All Welded Stainless Steel 16GA,
Type 304 Pressure Tight Design
Diffuser for Air Supply (Metal) Non-Flammable Non-Flammable

HEPA Filter Seal Type:

Supply Filter-99.99% Eff. on 0.3 Microns

Exhaust Filter-99.99% Eff. on 0.3 Microns

HEPEX Seal
Neoprene, Spring loaded
HEPEX Seal
Neoprene, Spring loaded
Fumigation per NIH/NSF Procedure Yes Yes

Standard Services:

Service Coupling (3/8 inch NPT) Left Middle, Left Bottom, Right Middle Left Middle, Left Bottom, Right Middle
Gas Valve/Service Coupling (3/8 inch NPT) Right Bottom Right Bottom
Duplex Outlet One, Left Front Faring One, Left Front Faring

Optional Services:

Gas Cocks 3/8" NPT Up to 3 ea. Sidewall Up to 3 ea. Sidewall
Remote Controlled Valves* Up to 3 ea. Sidewall Up to 3 ea. Sidewall
Ultraviolet Light One, Backwall One, Backwall

Cabinet Size Inches (mm):

Height (Fully Assembled) (Incl. Exh Filter Fastener)  62 (1575) 62 (1575)
Height (Minimum for Transport) 62 (1575) 62 (1575)
Width 53 5/8 (1362) 53 5/8 (1362)
Depth (with Armrest removed) 31 7/16 (798) 31 7/16 (798)
Work Access Opening Inches (mm): Standard Opening Height 8 (203) 8 (203)
Standard Inflow Velocity 105 FPM (0.53 m/s) 105 FPM (0.53 m/s)

Work Zone Inches (mm):

Height 25 3/16 (640) 25 3/16 (640)
Width 46 3/8 (1178) 70 3/8 (1788)
Depth measured at 8 inches (203mm) 26 (660) 26 (660)

Viewing Window Inches (mm):

   
Standard is Tempered Sliding Glass
Hinged Tempered Glass (optional)
1.0 (25mm) Closed 18 1/2 (470) Open
8 (203) Access Opening
1.0 (25mm) Closed 18 1/2 (470) Open
8 (203) Access Opening
Certification Exhaust Value CFM/CMH 740/1257 1122/1906
Concurrent Balance Value CFM/CMH + 815/1385 1275/2166
Plant Duct Static Pressure Eng./Metric 1.7 w.g./43mm w.g. 1.8 w.g./46mm w.g.
Heat Rejected, BTU, Per Hour 474 584

Electrical:

U.L./UL-C, US Listed 115 Volts, 60 Hz U.L./UL-C, US Listed 115 Volts, 60 Hz
Amps: Blower/Lights Amps: Outlet*** 2.1 2.6
Rated Amps: 8 10
12 ft. Power Cord (one) 14 GA - 3 Wire, 15A 14 GA - 3 Wire, 15A
Crated Shipping Weight: 540 lbs. / 245 kg. 730 lbs. / 331 kg.
Net Weight 490 lbs. / 222 kg. 680 lbs. / 308 kg.

* Remote controlled valve handles project through front fairing. Decorative side panels are available to cover plumbing.

** Concurrent Balance Value shall be used for design and balance exhaust/supply HVAC requirements. Values provided are nominal. Design tolerances should be added for measurement and system differences.

*** Based on a cabinet with new filters running at 115 VAC.

Download Resources
Reviews

Be the first to review this product

Write Your Own Review

Only registered users can write reviews. Please, log in or register