The In-VitroCell™ ES (Energy Saver) model NU-8600 is a CO2 Incubator that uses heated water that surrounds the growth chamber to created uniform temperature conditions for cell culture growth. Water Jacket model NU-8600 also uses an IR sensor to maintain proper CO2 gas levels and produces a humidified environment up to 95% perfect for mammalian cell studies.


Part #: NU-8600

Features

The In-VitroCell™ ES (Energy Saver) Water Jacket CO2 Incubator model NU-8600 maintains a consistent temperature and CO2 levels, providing an optimal growth environment for tissue cell cultures in its clean design chamber.


Technology

NuTouch Electronic Control System (ECS)

Control over the functions of the CO2 incubator is provided by the NuTouch ECS. This user-friendly control system lets operators program system use, calibration procedures, alarm parameters and they can also adapt the incubator to different lab environments. The ECS has a color touchscreen to enter data and view operating control parameters and status indicators.


Precise CO2 Control

A dual wave infrared (IR) CO2 sensor measures and maintains accurate growth-chamber CO2 levels in the range of ±0.1 percent and is not affected by water vapor or other components. The single light source dual-wave design delivers stable, drift-free output that requires less frequent calibration.


Contamination Control

Closed-Loop HEPA Filtration

The closed-loop HEPA filtration system creates an environment similar to an ISO Class 5 clean room minimizing contamination. A continuously operating air pump maintains a positive pressure growth environment as gas and air pass through the 99.99 percent efficient filters at a recirculation rate of one chamber volume change every 30 minutes.


Clean Design

The crevice-free, cove-cornered interior of the water jacket incubator discourages biological growth to help prevent contamination. It is constructed of 16-gauge polished stainless steel; a surface that is easy to keep clean and contaminant-free.


Vibration-Free Construction

The NU-8600 CO2 incubator is designed with few moving parts, minimizing potential vibration that disturbs cell lines.


Performance

Precise Temperature Control

The NU-8600 maintains accurate temperature with the large 18 gallons (68.1-liter) water jacket that surrounds the inner chamber. Heated water in this jacket circulates around the growth chamber, keeping the temperature uniform within the growth chamber ±0.2°C. Precise temperature control is aided by the R5 insulation that lines the outer chamber walls that minimize heat loss.

The door and perimeter heaters are microprocessor-controlled to adjust to the room's ambient temperature. They can also be adjusted manually from ±20 percent to reduce condensation within the growth chamber.


Faster Recovery Times

The CO2 level can recover automatically at an average rate of 5 percent in five minutes, while the temperature recovers at 0.12°C per minute. Faster recovery times ensure your cell lines remain undisturbed promoting cell growth.


Standard Features

  • 16-Gauge Type 304 Polished Stainless Steel Growth Chamber
  • 16-Gauge Type 304 Polished Stainless Steel Shelving (Qty 4)
  • NuTouch Electronic Control System (ECS)
  • Closed Loop HEPA Filtration System
  • Infrared (IR) Sensor
  • R5 Insulation System
  • Independent Door Heater
  • Right Hinge Swing Field Reversible Exterior Door
  • Right Hinge Swing Field Reversible Inner Glass Door
  • Removable/Autoclavable Inner Door Gasket
  • Water Fill Port
  • Drain Valve
  • Quantity Four (4) Shelves
  • Quantity Four (4) Wall Brackets
  • Quantity Eight (8) Shelf Guides
  • Heavy Duty Leg Levelers
  • USB Port
  • RJ-11 Communication Port for Remote Alarm Connection
  • RJ-45 Jack - RS-485 2-way Communication
    • Output: Control system levels and alarms/events
    • Input: Commands from a Computer to view and update operating parameters
  • RJ-45 Jack - 4-20 mA Analog Output for monitoring all active control system levels
  • Utility Access Port
  • Stainless Steel Water Pan
  • 8-foot (2.5m) electrical power cord
  • Field Stackable with Appropriate NuAire Incubator Models

Parts & Accessories
Use Cases
Options

Chamber

Part NumberDescription
8600I60 Stainless Steel Chamber
8600I61 Stainless Steel Chamber with Cooling Coil

Shelving

Part NumberDescription
8600I54 Stainless Steel Shelving (Qty 4)
8600I45 Copper Shelving (Qty 4)

Inner Door

Part NumberDescription
8600I59 Inner Glass Door with Cam Action Lock
8600I56 Gas Tight Inner Sectioned Door with Cam Action Lock

Built-in Options

Part NumberDescription
8600I55 Left Hinge Door Swing

Specs
Electrical Requirements
Models

NU-8600: 115V, 50/60Hz

NU-8600E: 230V, 50/60Hz

Quality Assurance UL, UL-C, CE

Dimensions
Exterior Dimensions (W x D x H)

25.625 x 27 x 37.75 in

649 x 685 x 958 mm

Foot Print (W x D)

22 x 17.5 in

557 x 445 mm

Interior Dimensions (W x D x H)

20.375 x 20.625 x 24 in

518 x 524 x 611 mm

Chamber Volume

5.65 ft3

160 Liter

Shelf Dimensions (W x D)

18 x 18.75 in

457 x 476 mm

Shelves Supplied (Standard) Quantity 4
Maximum Shelf Capacity

16

Maximum Weight Capacity

25 lbs (11.34 kg) per shelf

125 lbs (56.7 kg) per incubator

Water Pan Dimensions (W x D x H)

10 x 1.5 x 12 in

254 x 38 x 305 mm

Water Pan Capacity

2 Liters (Maximum)

1.5 Liters (Recommended Fill)

Volume

5.65 ft3

160 L

Net Weight (Including Water and Shelving)

403 lbs

183 kg


Temperature Control
Control Range:

5°C above ambient (to a 30°C max ambient) to 55°C

Set-Point Range: 5°C to 55°C (37.0 Default)
Uniformity: ±0.2°C @ 37°C
Accuracy: ± 0.1°C
Recovery: 0.12°C/min. on Average
Display Resolution: 0.1°C
Door and Perimeter Heater Control Logic: Proportional base duty cycle based on Temperature set point and 0-100% manually adjustable to adapt to ambient conditions.
Temperature Sensor Type: Precision Integrated Circuit

CO2 Control Standard
Range:

0.1 to 20% (default 5%). (0.0 set point idles system)

Accuracy: ±0.1%
CO2 Recovery: Up to 5% ±0.2% / -0.5 in 5 minutes Average
CO2 Display Resolution: 0.1%
CO2 Control Logic: Fixed Algorithm/Manual, Environmental Adaptable
CO2 Sensor Type: Infrared single source dual wave length