In-VitroCell NU-5841 Direct Heat CO2 Incubator
The In-VitroCell ES NU-5841 provides an easy method to monitor and control humidity and oxygen levels in the chamber for hypoxic stress studies, stem cell culture, carcinogenic tumors, toxicity, and more.
- Overview
- Specifications
- Reviews
- Resources
- Options
Overview
The In-VitroCell model NU-5841 is a direct heat CO2 incubator that features an RH sensor and water reservoir in place of a water pan to control the growth chamber's humidity levels to the setpoint. In addition, the NU-5841 also offers the ability to suppress oxygen levels by monitoring O2 levels in the chamber and injecting nitrogen gas to meet the setpoint. A large 7.06 ft3 (200 Liter) capacity chamber is a perfect solution for principal investigators looking for a robust solution for hypoxic stress studies, stem cell culture research, and more.
Specifications
| CO2 Accuracy | ± 0.1% |
| CO2 Control Logic | Fixed Algorithm/Manual, Environmental Adaptable |
| CO2 Display Resolution | 0.1% |
| CO2 Range | 0.1 to 20%, 5% Default Set Point |
| CO2 Recovery | Up to 5% ± 0.2% / -0.5 in 5 minutes Average |
| CO2 Sensor Type | Infrared (NDIR) |
| Segmented Doors | Option, Set of 6 Inner Doors, 2 Across by 3 Down |
| Access Port Location | Right Side |
| Chamber Air Filter | 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay |
| Exterior Door Seal | Magnetic Outer Door Gasket |
| Exterior Material | Cold Rolled 16 & 18 Gauge Steel, Finished in Powder Coated Polyurethane Finish |
| In-line Gas Filters | 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor |
| Inner Doors | One |
| Insulation | High Density Insulation with High "R" Rating |
| Interior Door Seal | Silicone Rubber Gasket |
| Interior Material | Polished Type 304L 16 Gauge Stainless Steel |
| Sample Port Location | Inner Glass Door |
| Shelf Capacity lbs (kg) | 25 lbs per Shelf / 125 lbs per Incubator |
| Shelf Material | Stainless Steel or Copper Alloy |
| Shelves | 4 Shelves Supplied, 20 Shelves Maximum Capacity |
| Data Output Features | RS-485, USB, 4-20mA |
| Remote Alarm Terminals | Standard |
| Est. Shipping Depth Inches (mm) | 31 (787) |
| Est. Shipping Height Inches (mm) | 51 (1219) |
| Est. Shipping Width Inches (mm) | 31 (787) |
| Exterior Depth Inches (mm) | 27.188 (691) |
| Exterior Height Inches (mm) | 39.688 (1008) |
| Exterior Width Inches (mm) | 26.750 (680) |
| Footprint Depth inches (mm) | 20.75 (527) |
| Footprint Width inches (mm) | 23.75 (603) |
| Interior Depth Inches (mm) | 20.053 (509) |
| Interior Height Inches (mm) | 28.500 (724) |
| Interior Volume Cubic Feet (Liters) | 7.06 (200) |
| Interior Width Inches (mm) | 21.257 (540) |
| Shelf Depth Inches (mm) | 18 3/4 (476) |
| Shelf Width Inches (mm) | 19 3/4 (502) |
| Water Pan Depth | 1.5 (38) |
| Water Pan Length Inches (mm) | 12 (305) |
| Water Pan Width | 10 (254) |
| Electrical Configuration | 115V60Hz |
| Power Cord Length Foot (Meter) | 8 (2.5) |
| Safety Certification | UL, UL-C |
| O2 Accuracy | ± 0.25% |
| O2 Control Logic | Fixed algorithm/ manual environmental adaptable |
| O2 Display Resolution | 0.1% |
| O2 Measuring Range | 0 - 25% |
| O2 Recovery | 5.0 ± 0.5% twenty minutes on Average |
| O2 Sensor Type | Zirconia Ceramic |
| O2 Set Point Range | 0.5 -21.0% (ambient) (21.0% Default) |
| Decontamination Cycle | 95°C Humidified Decontamination, 145°C Dry Decontamination Cycle |
| RH Accuracy | +5% /- 3% |
| RH Control Logic | Fixed algorithm/manual environmental adaptable |
| RH Control Method | Water Pan or Evaporator Box, Depending on Model |
| RH Control Range | Ambient dependent to 90% |
| RH Display Resolution | 0.1% |
| RH Evaporator Box Capacity | 3L |
| RH Recovery | 90% +5%/-3% within 25 minutes on average |
| RH Sensor Type | Precision capacitance bulk-polymer |
| RH Water Pan Capacity | 2L (Recommended Fill 1.5L) |
| Chamber Air Circulation Method | Air Pump |
| Chamber Jacket Technology | Air Jacket via One or Two Axial Fans Drawing Air into Shell |
| Control System | NuTouch |
| Chamber Heater(s) Location | Walls, Top and Bottom of Chamber |
| Door and Perimeter Heater Control Logic | Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable] |
| Temperature Accuracy °C | ± 0.1% |
| Temperature Control | Direct Heat |
| Temperature Control Range | 5°C above ambient (to a 30°C max ambient) to 55°C |
| Temperature Display Resolution | 0.1°C |
| Temperature Recovery | 0.12°C/min. on Average |
| Temperature Sensor Type | Precision Integrated Circuit |
| Temperature Set-Point Range | 5°C to 55°C (37.0°C Default) |
| Temperature Uniformity °C | ± 0.35°C @ 37°C |
| Est. Shipping Weight lbs (kg) | 325 (147) |
| Net Weight lbs (kg) | 235 (106) |
| CO2 Accuracy | ± 0.1% |
| CO2 Control Logic | Fixed Algorithm/Manual, Environmental Adaptable |
| CO2 Display Resolution | 0.1% |
| CO2 Range | 0.1 to 20%, 5% Default Set Point |
| CO2 Recovery | Up to 5% ± 0.2% / -0.5 in 5 minutes Average |
| CO2 Sensor Type | Infrared (NDIR) |
| Segmented Doors | Option, Set of 6 Inner Doors, 2 Across by 3 Down |
| Access Port Location | Right Side |
| Chamber Air Filter | 99.97% Efficiency @ ≥ 0.3 Micron Capsule Filter Located in Sensor Bay |
| Exterior Door Seal | Magnetic Outer Door Gasket |
| Exterior Material | Cold Rolled 16 & 18 Gauge Steel, Finished in Powder Coated Polyurethane Finish |
| In-line Gas Filters | 99.97% Efficiency @ ≥ 0.3 Micron Disk Filters for Gas & Air Supplies, Disk Filter for CO2 Sensor |
| Inner Doors | One |
| Insulation | High Density Insulation with High "R" Rating |
| Interior Door Seal | Silicone Rubber Gasket |
| Interior Material | Polished Type 304L 16 Gauge Stainless Steel |
| Sample Port Location | Inner Glass Door |
| Shelf Capacity lbs (kg) | 25 lbs per Shelf / 125 lbs per Incubator |
| Shelf Material | Stainless Steel or Copper Alloy |
| Shelves | 4 Shelves Supplied, 20 Shelves Maximum Capacity |
| Data Output Features | RS-485, USB, 4-20mA |
| Remote Alarm Terminals | Standard |
| Est. Shipping Depth Inches (mm) | 31 (787) |
| Est. Shipping Height Inches (mm) | 51 (1219) |
| Est. Shipping Width Inches (mm) | 31 (787) |
| Exterior Depth Inches (mm) | 27.188 (691) |
| Exterior Height Inches (mm) | 39.688 (1008) |
| Exterior Width Inches (mm) | 26.750 (680) |
| Footprint Depth inches (mm) | 20.75 (527) |
| Footprint Width inches (mm) | 23.75 (603) |
| Interior Depth Inches (mm) | 20.053 (509) |
| Interior Height Inches (mm) | 28.500 (724) |
| Interior Volume Cubic Feet (Liters) | 7.06 (200) |
| Interior Width Inches (mm) | 21.257 (540) |
| Shelf Depth Inches (mm) | 18 3/4 (476) |
| Shelf Width Inches (mm) | 19 3/4 (502) |
| Water Pan Depth | 1.5 (38) |
| Water Pan Length Inches (mm) | 12 (305) |
| Water Pan Width | 10 (254) |
| Electrical Configuration | 230V5060Hz |
| Power Cord Length Foot (Meter) | 8 (2.5) |
| Safety Certification | UL, UL-C |
| O2 Accuracy | ± 0.25% |
| O2 Control Logic | Fixed algorithm/ manual environmental adaptable |
| O2 Display Resolution | 0.1% |
| O2 Measuring Range | 0 - 25% |
| O2 Recovery | 5.0 ± 0.5% twenty minutes on Average |
| O2 Sensor Type | Zirconia Ceramic |
| O2 Set Point Range | 0.5 -21.0% (ambient) (21.0% Default) |
| Decontamination Cycle | 95°C Humidified Decontamination, 145°C Dry Decontamination Cycle |
| RH Accuracy | +5% /- 3% |
| RH Control Logic | Fixed algorithm/manual environmental adaptable |
| RH Control Method | Water Pan or Evaporator Box, Depending on Model |
| RH Control Range | Ambient dependent to 90% |
| RH Display Resolution | 0.1% |
| RH Evaporator Box Capacity | 3L |
| RH Recovery | 90% +5%/-3% within 25 minutes on average |
| RH Sensor Type | Precision capacitance bulk-polymer |
| RH Water Pan Capacity | 2L (Recommended Fill 1.5L) |
| Chamber Air Circulation Method | Air Pump |
| Chamber Jacket Technology | Air Jacket via One or Two Axial Fans Drawing Air into Shell |
| Control System | NuTouch |
| Chamber Heater(s) Location | Walls, Top and Bottom of Chamber |
| Door and Perimeter Heater Control Logic | Base Duty Cycle set to chamber temperature Set-Point, Proportional 0-100% [manually adjustable] |
| Temperature Accuracy °C | ± 0.1% |
| Temperature Control | Direct Heat |
| Temperature Control Range | 5°C above ambient (to a 30°C max ambient) to 55°C |
| Temperature Display Resolution | 0.1°C |
| Temperature Recovery | 0.12°C/min. on Average |
| Temperature Sensor Type | Precision Integrated Circuit |
| Temperature Set-Point Range | 5°C to 55°C (37.0°C Default) |
| Temperature Uniformity °C | ± 0.35°C @ 37°C |
| Est. Shipping Weight lbs (kg) | 325 (147) |
| Net Weight lbs (kg) | 235 (106) |
Review
Resources
Brochures
Drawings
Videos
Specifications
BIM Revit
Request Your Quote for a NU-5841
Please fill out the form below for a lab equipment quote and we'll get to work on getting you what you need. Need to talk with someone right away? Give us a call at 763-553-1270.
Thank you for completing the form.
We will be in touch. If you have any urgent questions, please reach out at 763-553-1270.