AireGard NU-140 Vertical Laminar Airflow Workstation

The AireGard™ NU-140 generates HEPA-filtered, ISO Class 5 vertical laminar airflow to provide product protection for sterile but non-hazardous drug compounding or non-hazardous work in microbiology.

Overview

The AireGard™ NU-140 generates HEPA-filtered vertical laminar airflow to provide product protection for sterile but non-hazardous drug compounding or non-hazardous work in microbiology and research labs. The DC ECM motor draws air through a pre-filter and propels it through a HEPA filter to create an ISO Class 5 level of air cleanliness inside a work zone surrounded by stainless steel walls and a work surface made of stainless steel with a PVC core. One easily monitors workbench performance through the Aeromax™ control system that visualizes pressure in the internal airflow plenum. The work zone comes standard with cord-pass throughs and fluorescent lighting but can be optionally configured with polycarbonate walls, an IV bar, LED lighting, outlets, and service valves to meet the demands of your pharmacy or lab’s workflow. It is the only model that can be fitted with a UV light and sliding window.

HEPEX Flexible Air Plenum

Experience a safer work environment with NuAire's innovative, flexible plenum design, harmonized with an ultra-high efficiency DC ECM motor, not only to uniformly distribute downflow air across the supply HEPA filter for laminar airflow in the work zone but also to reduce sound and vibration significantly. This unique system also promotes even filter loading, extending HEPA filter longevity and ensuring your focus stays on your critical work, undisturbed.

AireGard NU-140 Vertical Laminar Airflow Workstation HEPEX flexible air plenum.

Stainless Steel Workzone

Crafted for optimizing aseptic technique, the durable stainless steel walls and work surface, fortified with a PVC core, offer an effortlessly cleanable work zone essential for maintaining pristine conditions. With two standard cord pass-throughs, it's ideal for seamlessly powering TPN Compounding Systems or Thermocyclers for PCR. It is an impeccable primary engineering control in pharmacies or as a sterile air workbench in microbiology labs, ensuring an uncompromised, easily maintainable, clean environment.

AireGard NU-140 Vertical Laminar Airflow Workstation features a smooth work zone.

AeroMax Control System

Experience ease of use like never before with our Aeromax control system. Designed for simplicity, it uses intuitive multicolored lights to display airflow performance. Plus, should workbench performance deviate from the norm, both visual and audible alarms ensure clarity and quick understanding. Simplify your operations with user-friendly electronic controls.
AeroMax Electronic Control System for Lab Equipment

Ultra High Efficiency Motor

Experience significant energy savings with our ultra-high efficiency DC ECM motor. Not only does it operate with reduced noise, but its optimal power also prolongs HEPA filter life. This means considerable long-term savings, reducing the total cost of ownership for your pharmacy or laboratory. Dive into a future of eco-friendly efficiency and lasting savings.

Ultra high efficiency motor for lab equipment

Specifications

AireGard NU-140 Vertical Laminar Flow Hood
Airflow Direction Vertical
Construction 16/18 GA, powder coated steel exterior; 16/18 GA type 304 SST work zone
Diffuser Metal Non-flammable
HEPA Filter Seal Type HEPEX Seal- Neoprene, Spring-loaded
IV Bar with 6 Hooks Optional
Motor(s) 1/3 HP DC ECM
Plenum Type HEPEX
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Work Access Opening(s) 25 1/4-inches (643mm) without UV Light, 20-inches (507mm) with UV Light
Est. Shipping Depth Inches (mm) 43 (1093)
Est. Shipping Height Inches (mm) 69 (1753)
Est. Shipping Width Inches (mm) 46 (1169)
Exterior Depth Inches (mm) 32 (813)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 86 1/2 (2197)
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 92 1/2 (2351)
Exterior Width Inches (mm) 38 (965)
Footprint Depth inches (mm) 32 (814)
Work Area Depth Inches (mm) 26 3/4 (679)
Work Area Height Inches (mm) 30 1/8 (765)
Work Area Width Inches (mm) 33 7/8 (860)
Power Cord 12 ft., 14 GA-3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Performance Standard IEST-RP-CC002.4, ISO 14644-1
Safety Certification UL-C, US
Air Cleanliness (ISO 14644) ISO Class 5
Airflow Velocity 90 fpm (0.46 m/s)
Airflow Volume at 90 fpm (0.46 mps) 503 (855)
Heat Rejected (BTU/Hour) 863
Protection Product
Control System AeroMax
Net Weight lbs (kg) 300 (136)
Airflow Direction Vertical
Construction 16/18 GA, powder coated steel exterior; 16/18 GA type 304 SST work zone
Diffuser Metal Non-flammable
HEPA Filter Seal Type HEPEX Seal- Neoprene, Spring-loaded
IV Bar with 6 Hooks Optional
Motor(s) 1/2 HP DC ECM
Plenum Type HEPEX
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Work Access Opening(s) 25 1/4-inches (643mm) without UV Light, 20-inches (507mm) with UV Light
Est. Shipping Depth Inches (mm) 43 (1093)
Est. Shipping Height Inches (mm) 69 (1753)
Est. Shipping Width Inches (mm) 58 (1474)
Exterior Depth Inches (mm) 32 (814)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 84 1/2 (2146) with 27 7/8-inch (709mm) Work Surface Height, Base with LL
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 92 1/2 (2350) with 35 7/8-inch (912mm) Work Surface Height, Base with LL
Exterior Width Inches (mm) 50 (1270)
Footprint Depth inches (mm) 32 (814)
Work Area Depth Inches (mm) 26 3/4 (679) on work surface / 24 7/8 (630) at window access height
Work Area Height Inches (mm) 30 1/8 (765)
Work Area Width Inches (mm) 45 7/8 (1165)
Power Cord 12 ft., 14 GA-3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Performance Standard IEST-RP-CC002.4, ISO 14644-1
Safety Certification UL-C, US
Air Cleanliness (ISO 14644) ISO Class 5
Airflow Velocity 90 fpm (0.46 m/s)
Airflow Volume at 90 fpm (0.46 mps) 681 (1158)
Heat Rejected (BTU/Hour) 1256
Protection Product
Control System AeroMax
Net Weight lbs (kg) 355 (161)
Airflow Direction Vertical
Construction 16/18 GA, powder coated steel exterior; 16/18 GA type 304 SST work zone
Diffuser Metal Non-flammable
HEPA Filter Seal Type HEPEX Seal- Neoprene, Spring-loaded
IV Bar with 6 Hooks Optional
Motor(s) 1/2 HP DC ECM
Plenum Type HEPEX
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Work Access Opening(s) 25 1/4-inches (643mm) without UV Light, 20-inches (507mm) with UV Light
Est. Shipping Depth Inches (mm) 43 (1093)
Est. Shipping Height Inches (mm) 68 (1728)
Est. Shipping Width Inches (mm) 77 (1956)
Exterior Depth Inches (mm) 32 (814)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 84 1/2 (2146) with 27 7/8-inch (709mm) Work Surface Height, Base with LL
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 92 1/2 (2350) with 35 7/8-inch (912mm) Work Surface Height, Base with LL
Exterior Width Inches (mm) 62 (1575)
Footprint Depth inches (mm) 32 (814)
Work Area Depth Inches (mm) 26 3/4 (679) on work surface / 24 7/8 (630) at window access height
Work Area Height Inches (mm) 30 1/8 (765)
Work Area Width Inches (mm) 57 7/8 (1470)
Power Cord 12 ft., 14 GA-3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Performance Standard IEST-RP-CC002.4, ISO 14644-1
Safety Certification UL-C, US
Air Cleanliness (ISO 14644) ISO Class 5
Airflow Velocity 90 fpm (0.46 m/s)
Airflow Volume at 90 fpm (0.46 mps) 859 (1460)
Heat Rejected (BTU/Hour) 1648
Protection Product
Control System AeroMax
Net Weight lbs (kg) 420 (191)
Airflow Direction Vertical
Construction 16/18 GA, powder coated steel exterior; 16/18 GA type 304 SST work zone
Diffuser Metal Non-flammable
HEPA Filter Seal Type HEPEX Seal- Neoprene, Spring-loaded
IV Bar with 6 Hooks Optional
Motor(s) 1/2 HP DC ECM
Plenum Type HEPEX
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Work Access Opening(s) 25 1/4-inches (643mm) without UV Light, 20-inches (507mm) with UV Light
Est. Shipping Depth Inches (mm) 43 (1093)
Est. Shipping Height Inches (mm) 68 (1728)
Est. Shipping Width Inches (mm) 82 (2083)
Exterior Depth Inches (mm) 32 (814)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 84 1/2 (2146) with 27 7/8-inch (709mm) Work Surface Height, Base with LL
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 92 1/2 (2350) with 35 7/8-inch (912mm) Work Surface Height, Base with LL
Exterior Width Inches (mm) 74 (1880)
Footprint Depth inches (mm) 32 (814)
Work Area Depth Inches (mm) 26 3/4 (679) on work surface / 24 7/8 (630) at window access height
Work Area Height Inches (mm) 30 1/8 (765)
Work Area Width Inches (mm) 69 7/8 (1775)
Power Cord 12 ft., 14 GA-3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Performance Standard IEST-RP-CC002.4, ISO 14644-1
Safety Certification UL-C, US
Air Cleanliness (ISO 14644) ISO Class 5
Airflow Velocity 90 fpm (0.46 m/s)
Airflow Volume at 90 fpm (0.46 mps) 1037 (1763)
Heat Rejected (BTU/Hour) 1962
Protection Product
Control System AeroMax
Net Weight lbs (kg) 565 (256)
Airflow Direction Vertical
Construction 16/18 GA, powder coated steel exterior; 16/18 GA type 304 SST work zone
Diffuser Metal Non-flammable
HEPA Filter Seal Type HEPEX Seal- Neoprene, Spring-loaded
IV Bar with 6 Hooks Optional
Motor(s) 1/3 HP DC ECM
Plenum Type HEPEX
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Work Access Opening(s) 25 1/4-inches (643mm) without UV Light, 20-inches (507mm) with UV Light
Est. Shipping Depth Inches (mm) 43 (1093)
Est. Shipping Height Inches (mm) 69 (1753)
Est. Shipping Width Inches (mm) 46 (1169)
Exterior Depth Inches (mm) 32 (814)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 84 1/2 (2146) with 27 7/8-inch (709mm) Work Surface Height, Base with LL
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 92 1/2 (2350) with 35 7/8-inch (912mm) Work Surface Height, Base with LL
Exterior Width Inches (mm) 38 (965)
Footprint Depth inches (mm) 32 (814)
Work Area Depth Inches (mm) 26 3/4 (679) on work surface / 24 7/8 (630) at window access height
Work Area Height Inches (mm) 30 1/8 (765)
Work Area Width Inches (mm) 33 7/8 (860)
Power Cord 12 ft., 14 GA-3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Performance Standard IEST-RP-CC002.4, ISO 14644-1
Safety Certification UL-C, US
Air Cleanliness (ISO 14644) ISO Class 5
Airflow Velocity 90 fpm (0.46 m/s)
Airflow Volume at 90 fpm (0.46 mps) 503 (855)
Heat Rejected (BTU/Hour) 863
Protection Product
Control System AeroMax
Net Weight lbs (kg) 300 (136)
Airflow Direction Vertical
Construction 16/18 GA, powder coated steel exterior; 16/18 GA type 304 SST work zone
Diffuser Metal Non-flammable
HEPA Filter Seal Type HEPEX Seal- Neoprene, Spring-loaded
IV Bar with 6 Hooks Optional
Motor(s) 1/2 HP DC ECM
Plenum Type HEPEX
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Work Access Opening(s) 25 1/4-inches (643mm) without UV Light, 20-inches (507mm) with UV Light
Est. Shipping Depth Inches (mm) 43 (1093)
Est. Shipping Height Inches (mm) 69 (1753)
Est. Shipping Width Inches (mm) 58 (1474)
Exterior Depth Inches (mm) 32 (814)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 84 1/2 (2146) with 27 7/8-inch (709mm) Work Surface Height, Base with LL
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 92 1/2 (2350) with 35 7/8-inch (912mm) Work Surface Height, Base with LL
Exterior Width Inches (mm) 50 (1270)
Footprint Depth inches (mm) 32 (814)
Work Area Depth Inches (mm) 26 3/4 (679) on work surface / 24 7/8 (630) at window access height
Work Area Height Inches (mm) 30 1/8 (765)
Work Area Width Inches (mm) 45 7/8 (1165)
Power Cord 12 ft., 14 GA-3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Performance Standard IEST-RP-CC002.4, ISO 14644-1
Safety Certification UL-C, US
Air Cleanliness (ISO 14644) ISO Class 5
Airflow Velocity 90 fpm (0.46 m/s)
Airflow Volume at 90 fpm (0.46 mps) 681 (1158)
Heat Rejected (BTU/Hour) 1256
Protection Product
Control System AeroMax
Net Weight lbs (kg) 355 (161)
Airflow Direction Vertical
Construction 16/18 GA, powder coated steel exterior; 16/18 GA type 304 SST work zone
Diffuser Metal Non-flammable
HEPA Filter Seal Type HEPEX Seal- Neoprene, Spring-loaded
IV Bar with 6 Hooks Optional
Motor(s) 1/2 HP DC ECM
Plenum Type HEPEX
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Work Access Opening(s) 25 1/4-inches (643mm) without UV Light, 20-inches (507mm) with UV Light
Est. Shipping Depth Inches (mm) 43 (1093)
Est. Shipping Height Inches (mm) 68 (1728)
Est. Shipping Width Inches (mm) 77 (1956)
Exterior Depth Inches (mm) 32 (814)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 84 1/2 (2146) with 27 7/8-inch (709mm) Work Surface Height, Base with LL
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 92 1/2 (2350) with 35 7/8-inch (912mm) Work Surface Height, Base with LL
Exterior Width Inches (mm) 62 (1575)
Footprint Depth inches (mm) 32 (814)
Work Area Depth Inches (mm) 26 3/4 (679) on work surface / 24 7/8 (630) at window access height
Work Area Height Inches (mm) 30 1/8 (765)
Work Area Width Inches (mm) 57 7/8 (1470)
Power Cord 12 ft., 14 GA-3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Performance Standard IEST-RP-CC002.4, ISO 14644-1
Safety Certification UL-C, US
Air Cleanliness (ISO 14644) ISO Class 5
Airflow Velocity 90 fpm (0.46 m/s)
Airflow Volume at 90 fpm (0.46 mps) 859 (1460)
Heat Rejected (BTU/Hour) 1648
Protection Product
Control System AeroMax
Net Weight lbs (kg) 420 (191)
Airflow Direction Vertical
Construction 16/18 GA, powder coated steel exterior; 16/18 GA type 304 SST work zone
Diffuser Metal Non-flammable
HEPA Filter Seal Type HEPEX Seal- Neoprene, Spring-loaded
IV Bar with 6 Hooks Optional
Motor(s) 1/2 HP DC ECM
Plenum Type HEPEX
Style Bench top, optional base stand
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Work Access Opening(s) 25 1/4-inches (643mm) without UV Light, 20-inches (507mm) with UV Light
Est. Shipping Depth Inches (mm) 43 (1093)
Est. Shipping Height Inches (mm) 68 (1728)
Est. Shipping Width Inches (mm) 82 (2083)
Exterior Depth Inches (mm) 32 (814)
Exterior Height with 30-inch (762 mm) Work Surface Height inches (mm) 84 1/2 (2146) with 27 7/8-inch (709mm) Work Surface Height, Base with LL
Exterior Height with 36-inch (915 mm) Work Surface Height inches (mm) 92 1/2 (2350) with 35 7/8-inch (912mm) Work Surface Height, Base with LL
Exterior Width Inches (mm) 74 (1880)
Footprint Depth inches (mm) 32 (814)
Work Area Depth Inches (mm) 26 3/4 (679) on work surface / 24 7/8 (630) at window access height
Work Area Height Inches (mm) 30 1/8 (765)
Work Area Width Inches (mm) 69 7/8 (1775)
Power Cord 12 ft., 14 GA-3 Wire, 15A
Power Cord Length Foot (Meter) 12 (3.7)
Supply Filter 3-inch (76mm) 99.99% Efficiency on 0.3 microns
Performance Standard IEST-RP-CC002.4, ISO 14644-1
Safety Certification UL-C, US
Air Cleanliness (ISO 14644) ISO Class 5
Airflow Velocity 90 fpm (0.46 m/s)
Airflow Volume at 90 fpm (0.46 mps) 1037 (1763)
Heat Rejected (BTU/Hour) 1962
Protection Product
Control System AeroMax
Net Weight lbs (kg) 565 (256)

Review

Options

  • 3-feet (0.9 m)
  • 4-feet (1.2 m)
  • 5-feet (1.5 m)
  • 6-feet (1.8 m)
  • 115V, 60Hz, 15 Amp, NEMA 5-15P, Made in USA
  • 230V, 50/60 Hz, 15 Amp, Plug Type F, Made in USA
  • Stainless Steel Sidewalls with Cord Pass Through each Side Wall
  • Polycarbonate Sidewalls with Cord Pass Through each Side Wall
  • No IV Bar, Field Retrofittable
  • IV Bar with 6 Hooks, 3 Height Locations
  • No UV Light, Non Field Retrofittable
  • UV Light, Backwall
  • Left Top Service Valve
  • Left Middle Service Valve
  • Left Bottom Service Valve
  • Right Top Service Valve
  • Right Middle Service Valve
  • Right Bottom Service Valve
  • Duplex Outlet - GFI (Qty 1) (NEMA 5-15R) (115V) (Mounted under work surface, field install, dedicated power cord NEMA 5-15P)
  • Duplex Outlet - (Qty 1) (NEMA 5-15R) (115V) (Mounted under work surface, field install, dedicated power cord NEMA 5-15P)
  • Telescoping Base Stand with Leg Levelers
  • Telescoping Base Stand with Casters
  • Telescoping Base Stand OPM Preapproved Seismic Design with Leg Levelers
  • Motorized Adjustable Base Stand with Leg Levelers
  • Motorized Adjustable Base Stand with Casters
  • Motorized Adjustable Seismic Base Stand
  • Base Stand Shelf, 8-inches (203 mm) for Telescoping Base Stand
  • Base Stand Shelf, 12-inches (305 mm) for Telescoping Base Stand
  • ErgoTron Monitor and Keyboard Workstation for Telescoping Base Stand
  • ErgoTron Workstation for Motorized Adjustable Base Stand
  • Seismic Brackets, Rear Mount for Telescoping Base Stand
  • Seismic Brackets, Rear Mount for 4-feet (1.2m) Motorized Base Stand
  • Seismic Brackets, Floor Mount for Telescoping Base Stand
  • Rear Closure Panel for 4-feet (1.2m) Cabinet Width

Request Your Quote for a NU-140

Please fill out the form below for a lab equipment quote and we'll get to work on getting you what you need. Need to talk with someone right away? Give us a call at 763-553-1270.

Thank you for completing the form.

We will be in touch. If you have any urgent questions, please reach out at 763-553-1270.