PharmaGard NU-NR800E Purchase Specifications (230V)

PharmaGard NU-NR800E Purchase Specifications (230V)

The PharmaGard NU-NR800E is a negative pressure recirculating Compounding Aseptic Containment Isolator (CACI) configured for 230V electrical systems. Available in 1.2 meter (400E) and 1.8 meter (600E) configurations, it maintains ISO Class 5 sterile conditions for USP 800 and NIOSH-compliant hazardous drug compounding. These purchase specifications define construction, performance, and electrical requirements.

About This Document

This page provides the purchase specifications (PSP-0035 Rev 1) for the PharmaGard NU-NR800E, a 230VAC Compounding Aseptic Containment Isolator from NuAire’s PharmaGard family. The document defines construction materials, performance requirements, airflow parameters, electrical specifications, and standard features for both the 1.2 meter (NU-NR800-400E) and 1.8 meter (NU-NR800-600E) models. Use these specifications to verify site readiness, write procurement language, or confirm that the NU-NR800E meets your facility’s engineering and pharmacy standards before purchase.

Available Models

The NU-NR800E is available in two nominal sizes. Both models share the same depth, interchange dimensions, and compliance specifications. Download the purchase specifications document for complete dimensional, exhaust, and electrical data.

NU-NR800-400E: 1.2 meter 230V CACI

The 4-foot model provides a narrower footprint suitable for facilities with limited cleanroom floor space, while maintaining the full ISO Class 5 work zone, interchange, and FlowGard control system included on all NU-NR800E configurations.

NU-NR800-600E: 1.8 meter 230V CACI

The 6-foot model offers an extended work zone for higher-volume or multi-product compounding workflows. Exhaust volume and total unit weight increase proportionally; refer to the purchase specifications for site planning requirements.

Performance and Compliance Standards

The NU-NR800E maintains negative pressure in both the work zone and interchange throughout the compounding cycle, ensuring continuous containment of hazardous drug aerosols and particulates. Performance is certified to CETA CAG-002-2006, and the isolator is designed to meet the requirements of USP <800> Hazardous Drugs — Handling in Healthcare Settings, NIOSH guidelines for hazardous drug handling, and ASHP guidelines for handling hazardous drugs in health-system pharmacies.

ISO Class 5 airflow is produced and maintained by supply and exhaust HEPA filters rated 99.99% efficient at 0.3 microns. Both filters are secured with neoprene spring-loaded frames under negative pressure, eliminating bypass risk. The NU-NR800E is UL Listed for hospital and healthcare environments and is RoHS compliant.

Construction and Materials

The NU-NR800E is fabricated from welded 16-gauge Type 304 stainless steel throughout. The large front window is hinged, lockable, and set at a 10-degree slant to reduce glare and improve ergonomic access during compounding. A door interlock on the interchange prevents the inner door from opening while the outer door is open, preserving containment integrity during every material transfer.

Two minihelic gauges provide direct visual monitoring of pressure in both the work zone and the interchange. LED task lighting delivers a minimum 40 foot-candles (430 LUX) at the work surface. A 3-position IV bar with 6 hooks accommodates a range of compounding setups.

FlowGard Control System

The NU-NR800E includes NuAire’s FlowGard digital control system with an OLED display. The interface supports six languages: English, Spanish, German, French, Simplified Chinese, and Japanese. A DC brushless EC impeller with constant volume control automatically compensates for filter loading to maintain consistent airflow across the filter’s service life. An exhaust interlock activates when the blower starts, ensuring negative pressure is established before the work zone can be accessed.

Operator controls include a security password, filter life and blower hours display, and auto duration timers. These features support documentation requirements under USP <800> and streamline routine maintenance planning.

Optional Accessories

A range of accessories is available to configure the NU-NR800E for your pharmacy’s workflow. Options include an integrated sharps disposal system, gas-tight damper, flexible duct kits, base stand alternatives, storage pull-out trays, and individual gas and vacuum service valves. Contact NuAire or your authorized distributor to specify accessories and confirm site compatibility.

For the complete PharmaGard RABS product family, including the NU-PR797 CAI (USP <797>), the North American NU-NR800 CACI, and the total-exhaust NU-NTE800 CACI, see the PharmaGard Restricted Access Barrier Systems product family page.

Frequently Asked Questions

What is the PharmaGard NU-NR800E?

The NU-NR800E is a negative pressure recirculating Compounding Aseptic Containment Isolator (CACI) from NuAire’s PharmaGard family, configured for 230VAC electrical systems. It maintains an ISO Class 5, HEPA-filtered sterile environment with negative pressure in both the work zone and interchange for USP <800> and NIOSH-compliant hazardous drug compounding. It is available in 1.2 meter (NU-NR800-400E) and 1.8 meter (NU-NR800-600E) configurations.

How does the NU-NR800E differ from the standard NU-NR800?

The NU-NR800E is the 230VAC variant of the NU-NR800 CACI, supplied with a hospital-grade 230V power cord for use in facilities operating on 230V electrical systems. Construction, performance, containment, and compliance specifications are equivalent to the North American NU-NR800. Contact NuAire or your authorized distributor to confirm availability in your region.

What electrical supply does the NU-NR800E require?

The NU-NR800E operates on 230VAC, 50/60 Hz. Both models are supplied with a hospital-grade power cord. Consult the purchase specifications document for amperage draw by model and verify site electrical capacity and circuit protection requirements with your facilities team before installation.

Does the NU-NR800E require a dedicated exhaust duct connection?

No. The NU-NR800E is a recirculating CACI and does not require a dedicated exhaust duct connection for normal operation. An optional gas-tight damper and flexible duct kit are available if a facility exhaust connection is desired. Consult the purchase specifications document for exhaust volume requirements by model. For total-exhaust installations, NuAire also offers the NU-NTE800 CACI.

What compliance standards does the NU-NR800E meet?

The NU-NR800E is certified to CETA CAG-002-2006 and is designed to meet the requirements of USP <800>, NIOSH, and ASHP guidelines for hazardous drug handling. It is UL Listed for hospital and healthcare environments and is RoHS compliant.

{
“@context”: “https://schema.org”,
“@graph”: [
{
“@type”: “FAQPage”,
“mainEntity”: [
{
“@type”: “Question”,
“name”: “What is the PharmaGard NU-NR800E?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “The NU-NR800E is a negative pressure recirculating Compounding Aseptic Containment Isolator (CACI) from NuAire’s PharmaGard family, configured for 230VAC electrical systems. It maintains an ISO Class 5, HEPA-filtered sterile environment with negative pressure in both the work zone and interchange for USP 800 and NIOSH-compliant hazardous drug compounding. It is available in 1.2 meter (NU-NR800-400E) and 1.8 meter (NU-NR800-600E) configurations.”
}
},
{
“@type”: “Question”,
“name”: “How does the NU-NR800E differ from the standard NU-NR800?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “The NU-NR800E is the 230VAC variant of the NU-NR800 CACI, supplied with a hospital-grade 230V power cord for use in facilities operating on 230V electrical systems. Construction, performance, containment, and compliance specifications are equivalent to the North American NU-NR800.”
}
},
{
“@type”: “Question”,
“name”: “What electrical supply does the NU-NR800E require?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “The NU-NR800E operates on 230VAC, 50/60 Hz. Both models are supplied with a hospital-grade power cord. Consult the purchase specifications document for amperage draw by model and verify site electrical capacity and circuit protection requirements with your facilities team before installation.”
}
},
{
“@type”: “Question”,
“name”: “Does the NU-NR800E require a dedicated exhaust duct connection?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “No. The NU-NR800E is a recirculating CACI and does not require a dedicated exhaust duct connection for normal operation. An optional gas-tight damper and flexible duct kit are available if a facility exhaust connection is desired. For total-exhaust installations, NuAire also offers the NU-NTE800 CACI.”
}
},
{
“@type”: “Question”,
“name”: “What compliance standards does the NU-NR800E meet?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “The NU-NR800E is certified to CETA CAG-002-2006 and is designed to meet the requirements of USP 800, NIOSH, and ASHP guidelines for hazardous drug handling. It is UL Listed for hospital and healthcare environments and is RoHS compliant.”
}
}
]
},
{
“@type”: “BreadcrumbList”,
“itemListElement”: [
{
“@type”: “ListItem”,
“position”: 1,
“name”: “Home”,
“item”: “https://www.nuaire.com/”
},
{
“@type”: “ListItem”,
“position”: 2,
“name”: “Resources”,
“item”: “https://www.nuaire.com/resources”
},
{
“@type”: “ListItem”,
“position”: 3,
“name”: “PharmaGard NU-NR800E Purchase Specifications”,
“item”: “https://www.nuaire.com/resources/pharmagard-nu-nr800e-purchase-specifications”
}
]
},
{
“@type”: “DigitalDocument”,
“name”: “PharmaGard NU-NR800E Purchase Specifications”,
“identifier”: “PSP-0035 Rev 1”,
“description”: “Download NU-NR800E purchase specs — NuAire’s 230V CACI for USP 800 hazardous drug compounding. ISO Class 5, HEPA-filtered, CETA CAG-002 compliant.”,
“url”: “https://www.nuaire.com/wp-content/uploads/2026/07/PSP-0035-NU-NR800E-Purchase-Specifications.pdf”,
“encodingFormat”: “application/pdf”,
“datePublished”: “2026-06-01”,
“about”: “Compounding Aseptic Containment Isolator, hazardous drug compounding, USP 800, 230V”,
“publisher”: {
“@type”: “Organization”,
“name”: “NuAire, A Kewaunee Company”
}
}
]
}

Related: Download the NU-NR800E Operations & Maintenance Manual

View the Full Purchase Specifications for PharmaGard NU-NR800E (230V)