LabGard® ES AIR Limited NU-545 Class II, Type A2 Biosafety Cabinet

The LabGard® ES (Energy Saver) AIR Limited Model NU-545 Biological Safety Cabinet (BSC) is a primary engineering control in obtaining the optimum product quality while reducing the potential for exposure of both product and personnel to airborne biological or particulate chemical agents in low to moderate risk-hazard research and drug preparation or product operations, as prescribed by the Center for Disease Control (CDC) Atlanta, Georgia.


NSF/ANSI 49   UL Canada United States Listing

Part #: NU-545

Features

The LabGard (Energy Saver) AIR Limited model NU-545 is an NSF/ANSI 49 certified Class II, Type A2 biological safety cabinet delivering the long-lasting, high-quality performance you and your staff demand to protect you and your work.


Safety

Automatic Airflow Compensation

To maintain safe airflows, the LabGard Limited Edition automatically compensates for both filter loading and line voltage variance to provide you safe, constant airflow protection.


HEPEX Zero Leak Airflow SystemHEPEX Zero Leak Airflow

The HEPEX™ Zero Leak Airflow System provides quiet, uniform velocities throughout the entire sterile work zone. All positive pressure chambers and ducts are surrounded by a vacuum or negative air pressure relative to the room. This feature eliminates the possibility of cabinet and gasket leaks. Uneven particulate loading is prevented by maintaining high-static pressure over the entire filter surface assuring True Laminar Airflow.


Dynamic Air BarrierDynamic Air Barrier

Air exchanges within a Class II, Type A2 Biological Safety Cabinet, can occur 25 times per minute. This rapid air exchange system combined with an aerodynamic, ergonomic air foil and a significantly larger access opening creates the strongest air barrier, personnel protection, of any Biological Safety Cabinet.


True Laminar AirflowTrue Laminar Airflow

Unidirectional Airflow moving along parallel flow lines at a constant velocity minimizes air turbulence within the work zone. With proper techniques, activities within the work area can be performed safely minimizing the chance of cross-contamination.


Technology

TouchLink 2.0 Electronic Control System

TouchLink™ is an easy-to-use touch screen LCD which will operate and display all system functions. On / off functions for fluorescent and germicidal ultraviolet lights, blower motor, and interior outlets. Monitors high / low limits for down flow, inflow, and sliding window position. The password protected TouchLink ™ also contains a unique date/clock display and timer functions that can be used as a laboratory timer, purge timer, outlet timer, UV light timer, auto-run timer, night setback, or weekend turn-off. TOUCHLINK™ also contains diagnostic functions for a NSF trained service technician or certifier.


Real Time Airflow Monitoring

Using the same technology as your NSF Accredited Certifier, model NU-545 features digital dual thermistor airflow sensors in the down flow and exhaust flow air to monitor and control real-time airflow ensuring safe airflows based on air velocity instead of pressure inside the plenum.


Auto Decontamination

The automatic decontamination works in conjunction with hydrogen peroxide, chlorine dioxide, and paraformaldehyde systems. The process simultaneously runs the cabinet blower at a low rate during the decontamination cycle. This will aid in the process of distributing the decontaminant gas/vapor throughout the cabinet during the entire decontamination cycle. Window clamps securely create an air tight seal against an inner window gasket. The inlet port is connected to a connection point on top of the BSC. The outlet port is attached to a fitting on an auto decontamination exhaust seal plate.


ErgonomicsErgonomic Design

NuAire designs equipment for you that provides improved safety conditions; improved productivity; improved quality and reliability; and reduction of arm, shoulder, and neck strain that can contribute to common work place injuries.

  • ADA (Americans with Disabilities Act) Compliant
  • Shorter reach into the work zone
  • Recessed work tray and air foil
  • Forearm Support
  • Efficient work Zone
  • Expanded Vision Zone to Reduce Awkward Postures and Proper Lighting for Reduced Glare
  • Staggered sidewall service valves
  • Centrally located electronic control center
  • Ability to Sit or Stand at a Range of Heights
  • More knee space

Lower Total Cost of Ownership

Ultra-High Efficiency Motor

A single DC ECM motor with an optimally sized fan saves you up to 47%* off your electricity bill compared to previously used motor technologies.

*Comparing a DC ECM versus an AC PSC motor in a 4 Foot Type A2 BSC that runs 24/7 (8736 hours per year) using $0.09 per kWh.


LED Lighting

Exterior LED lighting provides life up to 50,000 hours and is 30% more efficient than standard fluorescent lightning. The LED lighting provides cool white illumination of the work zone from 90 – 120 foot-candles (968 – 1291 lux).


Larger, Longer Lasting Filters

NuAire offers filters that use more filter media and offer more pleats per square inch. Combined with an ultra-high efficiency motor with more torque, a NuAire BSC can extend the life of a HEPA filter up to 10 years or more.


Night Setback

As a standard option, upon window closure, the NU-545 may allow the motor to continue to run at a lower rate to continually HEPA filter the work zone. The LED light will be disabled. If the sliding window is then opened, the cabinet will resume normal airflow set points in run mode. Night setback will save your facility money if your standard operating procedures require you to run the BSC 24/7.


Design

Monolithic DesignMonolithic Design

At the core of any NuAire Biosafety Cabinet is the single piece stainless steel shell. The process starts by bending a single piece of heavy duty stainless steel to create the back and side walls of the cabinet. Additional stainless steel sheets are seam welded into place to create the top and bottom. A smaller sheet of stainless steel is bent and welded into place to create the coved interior work zone. The final step welds the frame work into place to house the motor/blower assembly and HEPA filters. The result is a monolithic shell eliminating the need for rivets, gaskets, and sealants extending product life and enhancing safety.


Vibration Control

The motor/blower system is suspended inside the BSC using the attenumont system, a shock absorbing technology minimizing vibration transfer from the motor to the cabinet. The HEPEX Zero Leak Airflow System uses an impermeable, antimicrobial, and flameproof flexible fabric to make up the BSC’s plenum eliminating vibration transfer from the motor/blower to the plenum.


Clean-ability

The interior of the BSC features smooth coved corners for easy clean-ability. A spill trough with drain valve is located under the work surface to catch any unwanted spills. The work surface comes optionally with a prop-up work tray to easily clean under the work surface.


Quality Advantage

Filter Integrity Check

Model NU-545 features larger 99.99% @ 0.3 μ efficiency HEPA filters that are tested using IEST Recommended Practices as prescribed by biosafety cabinetry standard NSF/ANSI 49. Exhaust and Supply HEPA filters feature more filter media equating to longer filter life and lower operating costs. HEPA filters are tested twice during the manufacturing process. Once before the filter is installed and again fitted in the biosafety cabinet before it ships. This integrity check process ensures you receive the safest biosafety cabinet out of the box with zero headaches. We believe in our process so much we included our filters in our warranty.


Biological Tolerance Testing Assures Optimal Performance

A Biological Safety Cabinet’s performance consists of a range of operational airflow parameters: air inflow and down flow velocities within a cabinet design will pass standard microbiological aerosol tests for personnel, product, and environmental protection. Effective Biological Safety Cabinet performance can be greatly affected by different laboratory conditions: Size of the laboratory, the location of the cabinet within a room, traffic patterns of laboratory personnel, electrical variations, airflow ducts and grills, and other equipment. The greater the extremes, the increased likelihood a cabinet will pass-the safer the cabinet design. NuAire® Class II Biological Safety Cabinets operate and can maintain maximum containment characteristics throughout a range of real world conditions.


Warranty

  • 5 Years Parts and Labor Warranty, Filters Included (United States and Canada)
  • 6 Years Parts Warranty, Filters Included (Worldwide)

Standard Features

  • Monolithic 16/18 Gauge, Type 304 Stainless Steel Welded Pressure Tight Construction (Silicone Free)
  • Ultra-high Efficiency Motor
  • TouchLink2 Electronic Control System
  • Intelliflow Airflow Monitoring
  • Automatic Filter Loading Compensation
  • Motor Speed Controller
  • Internal Exhaust Damper
  • NiteCare Night Setback
  • HEPEX Zero Leak Airflow System
  • Front Filter Removal
  • Permanent Plenum with Quick Release Supply Filter
  • Metal Diffuser Over Supply Filter
  • 3-inch (76 mm) Supply HEPA Filter 99.99 @ 0.3 Micron Efficiency Rating
  • 12-inch (305 mm) Exhaust HEPA filter 99.99 @ 0.3 Micron Efficiency Rating
  • Attenumont Vibration Control
  • Exterior LED Lighting
  • 10-inch [254 mm] Access Opening (NSF/ANSI 49)
  • Frameless Sliding Tempered Glass View Screen
  • Gasketed Window Frame
  • Heavy Duty, Ergonomic Plastic Armrest
  • Removable Work Tray
  • Work Surface Support System
  • Spill Trough with Drain Valve
  • Two Duplex Outlet Back-wall
  • One Service Valve Right Side Wall
  • One Service Coupling Right Side Wall
  • Two Service Couplings Left Side Wall
  • Power Cord

Specs

Catalog Number

Catalog Number

NU-545-300

Nominal 3 foot (0.9m)

NU-545-400

Nominal 4 foot (1.2m)

NU-545-500

Nominal 5 foot (1.5m)

NU-545-600

Nominal 6 foot (1.8m)

Performance Specifications

  1. Personal Protection

  2. Product Protection

NSF/ANSI 49

NSF/ANSI 49

NSF/ANSI 49

NSF/ANSI 49

NSF / ANSI 49

Class II, Type A2

Class II, Type A2

Class II, Type A2

Class II, Type A2

Style of Cabinet

Bench top/console w/base stand/storage cabinet

Bench top/console w/base stand/storage cabinet

Bench top/console w/base stand/storage cabinet

Bench top/console w/base stand/storage cabinet

Cabinet Construction

All welded stainless steel 16GA, Type 304

pressure tight design

All welded stainless steel 16GA, Type 304

pressure tight design

All welded stainless steel 16GA, Type 304

pressure tight design

All welded stainless steel 16GA, Type 304

pressure tight design

Diffuser for Air Supply (Metal)

Non-flammable

Non-flammable

Non-flammable

Non-flammable

HEPA Filter Seal Type:

Supply Filter-99.995% Eff. on 0.3 microns Exhaust Filter-99.995% Eff. on 0.3 microns

HEPEX Seal

Neoprene, Spring-loaded

HEPEX Seal

Neoprene, Spring-loaded

HEPEX Seal

Neoprene, Spring-loaded

HEPEX Seal

Neoprene, Spring-loaded

Fumigation : NSF / ANSI 49 Procedures

Yes

Yes

Yes

Yes

Standard Services:

Service Coupling (3/8 inch NPT)

Gas Valve/Service Coupling (3/8inch NPT) Outlet

One, Right Sidewall One, Right Sidewall Two, Backwall

One, Right Sidewall One, Right Sidewall Two, Backwall

One, Right Sidewall One, Right Sidewall Two, Backwall

One, Right Sidewall One, Right Sidewall Two, Backwall

Optional Services: Gas Cocks 3/8" NPT Ultraviolet Light Standard/Cup Sinks

Up to 3 ea. Sidewall One, Backwall

Left or Right Work Surface

Up to 3 ea. Sidewall One, Backwall

Left or Right Work Surface

Up to 3 ea. Sidewall One, Backwall

Left or Right Work Surface

Up to 3 ea. Sidewall One, Backwall

Left or Right Work Surface

Cabinet Size Inches (mm): Height (Fully Assembled)

Height (Minimum for Transport) Width Depth (with Control Center)

And Armrest Removed

60 7/8 (1546)

59 (1499)

41 5/8 (1057)

32 ¼ (819)

60 7/8 (1546)

59 (1499)

53 5/8 (1362)

32 ¼ (819)

60 7/8 (1546)

59 (1499)

65 5/8 (1669)

32 ¼ (819)

60 7/8 (1546)

59 (1499)

77 5/8 (1972)

32 ¼ (819)

Work Access Opening Inches (mm): Standard Opening Height/Optional Standard Inflow Velocity

10 (254) / 8 (203)

105 FPM (.53 m/s)

10 (254) / 8 (203)

105 FPM (.53 m/s)

10 (254) / 8 (203)

105 FPM (.53 m/s)

10 (254) / 8 (203)

105 FPM (.53 m/s)

Work Zone Inches (mm): Height

Width

Depth measured at 10 inches

(254mm) window height

28 1/2 (724)

34 3/8 (873)

26 (660)

28 1/2 (724)

46 3/8 (1178)

26 (660)

28 1/2 (724)

46 3/8 (1178)

26 (660)

28 1/2 (724)

70 3/8 (1788)

26 (660)

Viewing Window Inches (mm): Standard is safety plate sliding glass

Fully closed to 18 (457) open

Fully closed to 18 (457) open

Fully closed to 18 (457) open

Fully closed to 18 (457) open

Required Exhaust CFM/CMH Standard/Optional:

Canopy Variable Flow Thimble (NU-911)

Canopy Fixed Flow Thimble (NU-907)

10 (254) / 8 (203) opening CFM (CMH)

276-501 (649-851) /

226-450 (383-765)

320 (544) / 269 (457)

10(254) / 8(203) opening CFM (CMH)

363-588 (617-1000) /

295-520 (502-884)

426 (724) / 359 (610)

10(254) / 8(203) opening CFM (CMH)

451-676 (766-1149) /

365-590 (621-1003)

531 (902) / 445 (756)

10(254) / 8(203) opening CFM (CMH)

538-763 (915-1297) /

436-661 (741-1124)

634 (1077) / 532 (904)

Plant Duct Static Pressure Eng./Metric

0.05-0.1"/1.27-2.54mm

H2O

0.05-0.1"/1.27-2.54mm

H2O

0.05-0.1"/1.27-2.54mm

H2O

0.05-0.1"/1.27-2.54mm

H2O

Heat Rejected, BTU, Per Hour (non-vented)

(vented)

10 (254) / 8 (203) opening

903 / 826

120

10(254) / 8(203) opening 1140/1020

157

10(254) / 8(203) opening 1768/1611

198

10(254) / 8(203) opening 1884/1768

198

Electrical: Volts, AC 60 Hz

+Amps: Blower/Lights (10/8 openings) Amps: Duplex

Rated Amps:

12 ft. Power Cord (one)

U.L./U.L.-C Listed 115

2.3 / 2.1

3

10

14 GA - 3 Wire, 15A

U.L./U.L.-C Listed 115

2.9/2.6

3

14

12 GA - 3 Wire, 20A

U.L./U.L.-C Listed 115

4.5/4.1

3

16

12 GA-3 Wire,

20A

U.L./U.L.-C Listed 115

4.8/4.5

3

16

12 GA-3 Wire,

20A

Crated Shipping Weight:*** Net Weight

460 lbs. /209 kg. 410 lbs. /186 kg.

530 lbs. /240 kg. 480 lbs. /218 kg.

620 lbs. /281 kg. 570 lbs. /258 kg.

690 lbs. /313 kg. 640 lbs. /290 kg.

*15A Configuration does not include accessory outlet.

***Crated shipping weight does not include weight for accessories or options

+ Based on cabinet with new filters running at 115VAC.